AHL085I
DYNALLOC INFORMATION RETRIEVAL FOR GTF OUTPUT DATA SETS FAILED - RETURN CODE=return-code, REASON CODE=reason-code.

Explanation

The generalized trace facility (GTF) has attempted to locate its output data sets by using the information retrieval service of dynamic allocation (SVC 99), but the DYNALLOC macro has failed.
return-code
Return code from the DYNALLOC macro in general register 15.
reason-code
Reason code from the DYNALLOC macro.

System action

The system issues message AHL016I and ends GTF execution.

Operator response

Record this message and notify the system programmer.

System programmer response

Examine the return and reason codes specified in the message and see z/OS MVS Programming: Assembler Services Guide for the DYNALLOC macro return and reason codes.

Source

Generalized trace facility (GTF)

Module

AHLGTFI2