ADR758E
(ttt)-mmmmm(yy), VOLUME CHECKING FAILED FOR DATA SET dsname {IN CATALOG catalog_name}, reason_code

Explanation

The data set was not processed for one of the following reasons (reason_code):
1
The data set was extended onto another volume after the DFSMSdss step started. As a result, the volume information obtained by DFSMSdss was no longer accurate.
2
The data set no longer resides on the volume or volumes it resided on when the DFSMSdss step started. As a result, the volume information obtained by DFSMSdss was no longer accurate.
3
The catalog entry for the data set could not be located. The data set have been uncataloged or moved to a different catalog after the DFSMSdss step started.

System action

The data set is not processed. The return code is 8.

Operator response

None.

Programmer response

Ensure that the data set is not being simultaneously processed by another job, and rerun the job.

Source

DFSMSdss