ANTP0004E
xx ERROR ON LINK linkaddresslinkerror

Explanation

An error was encountered while attempting to establish a PPRC path with the specified link address. The error is described by a two digit error code and corresponding link error text.

xx
linkerror
02
INITIALIZATION FAILED
03
TIMEOUT
04
NO RESOURCES AVAILABLE AT PRIM
05
NO RESOURCES AVAILABLE AT SEC
06
SERIAL# MISMATCH
07
SEC SSID MISMATCH
08
ESCON® LINK FAILURE
09
ESTABLISH FAILED
0A
PATH ACTIVE TO HOST
0B
PATH TO SAME CLUSTER
10
CONFIGURATION ERROR
14
FCP LINK DOWN
15
FCP RETRY EXCEED
16
FCP SEC ADAPTER NOT PPRC CAPABLE
17
FCP SEC ADAPTER NOT AVAILABLE
18
FCP PRIMARY LOGIN EXCEEDED
19
FCP SECONDARY LOGIN EXCEEDED
1A
PRIMARY FIBER CHANNEL NOT CONFIG
1B
FIBRE DEGRADED
1C
FIBRE REMOVED

System action

The specified path is not established. If no other paths were successfully established by this command, and no volume pairs were previously established for the LSS pair, all path definitions associated with the LSS pair will be deleted. Otherwise, for the ESS and similar storage subsystems, the path definition will be retained by the subsystem which can automatically establish the path at a future time when the error condition has been resolved.

System programmer response

02 INITIALIZATION FAILED
Verify that the physical link, including ESCD ports, is correct for the connection you are attempting. Verify the integrity of the fiber-optic links between the requested source and the destination.
03 TIMEOUT
Verify the physical link at the primary storage control. Determine if non-PPRC system activity has degraded link response times during the establish time.
04 NO RESOURCES AVAILABLE AT PRIM
Verify that the primary storage control does not already have the maximum number of logical paths already established. Verify the configuration and remove any unnecessary channel paths.
05 NO RESOURCES AVAILABLE AT SEC
Verify that the recovery site storage control does not already have the maximum number of logical paths already established. Verify the configuration and remove any unnecessary channel paths.
06 SERIAL# MISMATCH
Verify the serial number of the recovery site storage control.
07 SEC SSID MISMATCH
Verify that the path is available and is properly defined.
08 ESCON LINK FAILURE
Verify that the ESCON Link is online.
09 ESTABLISH FAILED
0A PATH ACTIVE TO HOST
The system adapter has already established a link to the system server on this path.
0B PATH TO SAME CLUSTER
There is already an established path from this primary cluster to the secondary cluster.
10 CONFIGURATION ERROR
Correct the error for the link address and reissue the command.
14 FCP LINK DOWN
Correct the error for the link address and reissue the command.
15 FCP RETRY EXCEED
Correct the error for the link address and reissue the command.
16 FCP SEC ADAPTER NOT PPRC CAPABLE
Correct the error for the link address and reissue the command.
17 FCP SEC ADAPTER NOT AVAILABLE
Correct the error for the link address and reissue the command.
18 FCP PRIMARY LOGIN EXCEEDED
Correct the error for the link address and reissue the command.
19 FCP SECONDARY LOGIN EXCEEDED
Correct the error for the link address and reissue the command.
1A PRIMARY FIBER CHANNEL NOT CONFIG
Do the primary fiber channel configuration and reissue the command.
1B FIBRE DEGRADED
Determine the reason for the high failure rate on the Fibre Channel connection.
1C FIBRE REMOVED
Determine the reason for the high failure rate on the Fibre Channel connection.

If a link shows ''STATUS NOT RECOGNIZED'', note the error code and contact the storage subsystem vendor for assistance in diagnosing the problem.

Source

Peer to Peer Remote Copy (PPRC).