Explanation
An error was encountered while attempting to establish
a PPRC path with the specified link address. The error is described
by a two digit error code and corresponding link error text.
- xx
- linkerror
- 02
- INITIALIZATION FAILED
- 03
- TIMEOUT
- 04
- NO RESOURCES AVAILABLE AT PRIM
- 05
- NO RESOURCES AVAILABLE AT SEC
- 06
- SERIAL# MISMATCH
- 07
- SEC SSID MISMATCH
- 08
- ESCON® LINK FAILURE
- 09
- ESTABLISH FAILED
- 0A
- PATH ACTIVE TO HOST
- 0B
- PATH TO SAME CLUSTER
- 10
- CONFIGURATION ERROR
- 14
- FCP LINK DOWN
- 15
- FCP RETRY EXCEED
- 16
- FCP SEC ADAPTER NOT PPRC CAPABLE
- 17
- FCP SEC ADAPTER NOT AVAILABLE
- 18
- FCP PRIMARY LOGIN EXCEEDED
- 19
- FCP SECONDARY LOGIN EXCEEDED
- 1A
- PRIMARY FIBER CHANNEL NOT CONFIG
- 1B
- FIBRE DEGRADED
- 1C
- FIBRE REMOVED
System action
The specified path is not established.
If no other paths were successfully established by this command, and
no volume pairs were previously established for the LSS pair, all
path definitions associated with the LSS pair will be deleted. Otherwise,
for the ESS and similar storage subsystems, the path definition will
be retained by the subsystem which can automatically establish the
path at a future time when the error condition has been resolved.
System programmer response
- 02 INITIALIZATION FAILED
- Verify that the physical link, including ESCD ports, is correct
for the connection you are attempting. Verify the integrity of the
fiber-optic links between the requested source and the destination.
- 03 TIMEOUT
- Verify the physical link at the primary storage control. Determine
if non-PPRC system activity has degraded link response times during
the establish time.
- 04 NO RESOURCES AVAILABLE AT PRIM
- Verify that the primary storage control does not already have
the maximum number of logical paths already established. Verify the
configuration and remove any unnecessary channel paths.
- 05 NO RESOURCES AVAILABLE AT SEC
- Verify that the recovery site storage control does not already
have the maximum number of logical paths already established. Verify
the configuration and remove any unnecessary channel paths.
- 06 SERIAL# MISMATCH
- Verify the serial number of the recovery site storage control.
- 07 SEC SSID MISMATCH
- Verify that the path is available and is properly defined.
- 08 ESCON LINK FAILURE
- Verify that the ESCON Link
is online.
- 09 ESTABLISH FAILED
- 0A PATH ACTIVE TO HOST
- The system adapter has already established a link to the system
server on this path.
- 0B PATH TO SAME CLUSTER
- There is already an established path from this primary cluster
to the secondary cluster.
- 10 CONFIGURATION ERROR
- Correct the error for the link address and reissue the command.
- 14 FCP LINK DOWN
- Correct the error for the link address and reissue the command.
- 15 FCP RETRY EXCEED
- Correct the error for the link address and reissue the command.
- 16 FCP SEC ADAPTER NOT PPRC CAPABLE
- Correct the error for the link address and reissue the command.
- 17 FCP SEC ADAPTER NOT AVAILABLE
- Correct the error for the link address and reissue the command.
- 18 FCP PRIMARY LOGIN EXCEEDED
- Correct the error for the link address and reissue the command.
- 19 FCP SECONDARY LOGIN EXCEEDED
- Correct the error for the link address and reissue the command.
- 1A PRIMARY FIBER CHANNEL NOT CONFIG
- Do the primary fiber channel configuration and reissue the command.
- 1B FIBRE DEGRADED
- Determine the reason for the high failure rate on the Fibre Channel
connection.
- 1C FIBRE REMOVED
- Determine the reason for the high failure rate on the Fibre Channel
connection.
If a link shows ''STATUS NOT RECOGNIZED'', note the
error code and contact the storage subsystem vendor for assistance
in diagnosing the problem.
Source
Peer to Peer Remote Copy (PPRC).