ANTF0456E
FLASHCOPY QUERY REMOTE UNABLE TO COMMUNICATE TO SECONDARY SUBSYSTEM

Explanation

The FlashCopy® Query request was issued with the REMOTE(YES) keyword. When the request was sent to the Secondary subsystem, an error occurred. Any one of the following conditions, or other conditions, can cause this error.

System action

The command is rejected.

System programmer response

Ensure that the PPRC Secondary subsystem is functioning normally. Ensure that the REMOTE (PPRC Secondary) subsystem is communicating with the PPRC Primary subsystem. If not, correct the communications problems between the Primary and Secondary subsystems. The PPRC Query and Establish Paths commands can be used to restore communications. Resubmit the corrected FlashCopy Query REMOTE request.

Source

ESS FlashCopy