ADR837E
(ttt)-mmmmm(yy), FLASHCOPY CONSISTENCY GROUP TIMER HAS EXPIRED FOR LSS WHERE VOLUME volser RESIDES

Explanation

The copy of the volumes in the Consistency Group not be consistent because the FlashCopy® Consistency Group timer expired before all the volumes can be copied.

System action

DFSMSdss processing continues. The return code is 8.

Programmer response

Ensure you specified the correct verification volume. Determine if the FlashCopy Consistency Group timer value is reasonable. If copying a large number of volumes within one FlashCopy Consistency Group takes too long, consider copying a smaller group of volumes.

Source

DFSMSdss