ANTX8054W
XRC STATE DATA SET FULL FOR SESSION(sessionid). MONITORD DISABLED

Explanation

XRC attempts to write XRC monitor data to the state data set for session sessionid, but a data set full condition was detected for the state data set. The gathering of XRC monitor data has been disabled. The setting for the console command CTFLG MONITORD is set to OFF.

System action

XRC functions are active.

System programmer response

Allocate another named state data set, which is larger than your current state data set, and reissue the appropriate XSUSPEND commands to suspend your sessions. Copy your current state data set to the new state data set. Rename the current state data set to another unique name, then rename the new state data set to the old state data set name. Issue the XSTART command and appropriate XADD commands to resume your session. To ensure that you have allocated sufficient space for XRC monitor data, issue the console command F ANTAS001,CTFLG MONITORD ON. If XRC processing is successful with the new state data set, you can delete the old state data set.

Source

Extended remote copy (XRC).