For the generalized trace facility (GTF), a response to message AHL101A or AHL102A, or a control statement in the GTF parmlib member, caused the maximum number of PCIE function identifiers (PFIDs) or PFID ranges to be exceeded. GTF only accepts up to 256 PFIDs or PFID ranges.
GTF ignores all options on the line in the response or control statement that contains the error. The system continues processing, but GTF initialization does not continue until the error is corrected. If the error occurred in the GTF parmlib member, the system issues message AHL124I to identify the error source.
In your reply to this message, enter all options on the line again, but remove some of the PFIDs or PFID ranges, or consolidate multiple PFIDs or PFID ranges into a single range. If the error is in the GTF parmlib member, notify the system programmer.
If a GTF control statement caused the error, remove some of the PFIDs or PFID ranges, or consolidate multiple PFIDs or PFID ranges into a single range in the GTF parmlib member and restart GTF.