z/OS MVS Programming: Sysplex Services Reference
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Summary of Version-Dependent Parameter Functions

z/OS MVS Programming: Sysplex Services Reference
SA38-0658-00

The following table summarizes the allowed use of some of the specifications that can be made depending on the PLISTVER value specified.

Table 1. IXLLSTM Version Support
Keyword Version Notes®
AUTHCOMPARE 0 NO may be specified.
  1 NO or YES may be specified.
REQUEST 0 READ_LIST, READ_MULT, DELETE_MULT, or DELETE_ENTRYLIST may be specified.
  1 Same as version 0
  2 Same as version 1
  3 Same as version 2
  4 READ_LIST, READ_MULT, DELETE_MULT, DELETE_ENTRYLIST, DELETE_LIST, or MOVE_ENTRYLIST may be specified.
VERSCOMPARE 0 NO or YES may be specified.
  1 Same as version 0
  2 Same as version 1
  3 Same as version 2
  4 NO, YES, or BYENTRY may be specified.
VERSCOMPTYPE 0 EQUAL may be specified.
  1 EQUAL ro LESSOREQUAL may be specified.
KEYSCANTYPE 0 ENTRY may be specified.
  1 Same as version 0.
  2 Same as version 1.
  3 Same as version 2.
  4 ENTRY or SECONDARY may be specified.
KEYREQTYPE 0 EQUAL may be specified. GREATEROREQUAL and LESSOREQUAL may be specified for only REQUEST=READ_LIST.
  1 Same as version 0
  2 Same as version 1
  3 Same as version 2
  4 EQUAL, LESSOREQUAL, GREATEROREQUAL, or RANGE may be specified.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014