0 |
None. |
Meaning: If you specified a MODE value of ASYNCECB,
ASYNCEXIT, ASYNCTOKEN, or ASYNCNORESPONSE, the request has been successfully
initiated. The answer area (ANSAREA) fields will not contain valid
information until the asynchronous processing has completed. For any
other MODE value, the request has successfully completed. Action: - If you specified MODE=ASYNCECB, wait on the ECB you specified
in REQECB.
- If you specified MODE=ASYNCEXIT, the connection's complete exit
will be given control when the request has completed.
- If you specified MODE=ASYNCTOKEN, use REQTOKEN when calling IXLFCOMP
to determine when the request has completed.
|
4 |
xxxx0402 |
Equate Symbol: IXLRSNCODEASYNCH Meaning: The
request could not be processed synchronously. It will be processed
asynchronously. The answer area (ANSAREA) fields will not contain
valid information until the asynchronous processing has completed.
- If MODE=SYNCECB was specified, the ECB specified for REQECB will
be posted when the request has finished.
- If MODE=SYNCEXIT was specified, the connection's complete exit
will be given control when the request has finished.
- If MODE=SYNCTOKEN was specified, an asynchronous request token
was returned in the area specified by REQTOKEN. This request token
may be specified on the IXLFCOMP macro to determine when the request
has finished.
Action: - If you specified MODE=SYNCECB, wait on the ECB you specified in
REQECB.
- If you specified MODE=SYNCEXIT, the connection's complete exit
will be given control when the request has completed.
- If you specified MODE=SYNCTOKEN, use REQTOKEN when calling IXLFCOMP
to determine when the request has completed.
|
8 |
xxxx0801 |
Equate Symbol: IXLRSNCODEBADPARMLIST Meaning: Program
error. The parameter list for this request is not addressable. The
answer area (ANSAREA) fields are not valid.
Action: Verify
that: - The parameter list address is uncorrupted.
- The parameter list is addressable in the caller's primary address
space.
- If you are issuing this macro while disabled, the parameter list
resides in either page-fixed or DREF storage.
- If you are issuing this macro in AR-mode and you specified the
parameter list address using explicit register notation, the corresponding
access register was updated appropriately.
- If you are issuing this macro in AR-mode, SYSSTATE ASCENV=AR must
be issued before issuing this macro.
|
8 |
xxxx0804 |
Equate Symbol: IXLRSNCODEBADVERSIONNUM (or IXLRSNCODEBADVERSION#)
Meaning: The version number in the macro parameter list
is not compatible with the level of XES currently being used. The
answer area (ANSAREA) fields are not valid.
Action: - Verify that your program did not overlay the parameter list storage.
- Verify that your program was assembled with the correct macro
library for the release of MVS™ on
which your program is running.
|
8 |
xxxx080A |
Equate Symbol: IXLRSNCODEBADCONTOKEN Meaning: Program
error. The specified connect token (CONTOKEN) was not valid for one
of the following reasons:
- The user with the connection identifier represented by the token
has disconnected from the structure.
- The connector's task (the task that issued IXLCONN) ended.
- The specified token is not the token that was returned from IXLCONN.
- The request was issued from an address space other than the address
space in which IXLCONN was issued.
- The connect token was invalidated during rebuild.
- The connect token was invalidated by XES.
Note: The answer area (ANSAREA) fields are not valid.
Action: Take
the action with the corresponding meaning.
- Discontinue use of the structure. Perform recovery and cleanup
for the structure and check the protocol for the use of the structure
to determine why you did not know of the disconnection.
- Discontinue use of the structure. Perform recovery and cleanup
for the structure and check the protocol for the use of the structure
to determine why you did not know that the task ended.
- The contoken is returned in the CONACONTOKEN field of the answer
area specified on the IXLCONN request.
- Issue your request from the same address space the IXLCONN was
issued in.
- Wait for the rebuild to complete, and try again.
- Discontinue use of the structure. Perform recovery and cleanup
for the structure.
|
8 |
xxxx0824 |
Equate Symbol: IXLRSNCODEWRONGSTRTYPE Meaning: Program
error. The connection specified by CONTOKEN is not to a list structure.
Action: Specify
the appropriate CONTOKEN value, and rerun your program. The CONTOKEN
is returned in the answer area provided on the IXLCONN invocation.
The type of structure built is passed on the TYPE parameter of the
IXLCONN macro.
|
8 |
xxxx0838 |
Equate Symbol: IXLRSNCODEBADANSAREA Meaning: Program
error. The storage area specified by ANSAREA is not addressable.
Action: Ensure
that: - The answer area address specified by ANSAREA is valid.
- If the caller is running in AR-mode and the ANSAREA parameter
was specified using explicit register notation, the corresponding
access register was updated appropriately.
- The address specified for ANSAREA is addressable in the caller's
primary address space or from the caller's PASN access list.
- If you are calling IXLLIST while disabled, ANSAREA must reside
in either page-fixed or DREF storage.
- If you are calling IXLLIST in AR-mode, SYSSTATE ASCENV=AR must
be issued before the IXLLIST macro.
|
8 |
xxxx0839 |
Equate Symbol: IXLRSNCODEBADREQTOKENAREA Meaning: Program
error. The storage area specified by REQTOKEN is not addressable.
Action: Ensure
that: - The request token area specified by REQTOKEN is valid.
- If the caller is running in AR-mode and the REQTOKEN parameter
was specified using explicit register notation, the corresponding
access register was updated appropriately.
- If you are calling IXLLIST while disabled, REQTOKEN must reside
in either page-fixed or DREF storage.
- If you are calling IXLLIST in AR-mode, SYSSTATE ASCENV=AR must
be issued before the IXLLIST macro.
|
8 |
xxxx083D |
Equate Symbol: IXLRSNCODEBADANSLEN Meaning: Program
error. The length of the answer area, as specified by ANSLEN, is not
sufficient to contain answer area information. The answer area (ANSAREA)
fields do not contain valid information.
Action: Increase
the size of the answer area, and rerun your program. The minimum size
of the ANSAREA is in the LAA_LEN field of the IXLYLAA mapping macro.
|
8 |
xxxx084A |
Equate Symbol: IXLRSNCODENOKEYS Meaning: Program
error. The structure does not support the use of entry keys. The
IXLLIST request type either required the structure to support entry
keys or designated a list entry or list position by list number and
entry key.
Action: Ensure that you are connected to
the intended structure. The use of keys for a structure is determined
by the REFOPTION keyword on the IXLCONN macro.
|
8 |
xxxx0851 |
Equate Symbol: IXLRSNCODENOSUSPENDISABLE Meaning: Program
error. The request failed because MODE=SYNCSUSPEND was specified,
but the caller is disabled and cannot be suspended.
Action: Either
specify another MODE value, or become enabled (release the CPU lock),
then reissue the request.
|
C |
xxxx0C06 |
Equate Symbol: IXLRSNCODENOCONN Meaning: Environmental
error. This system does not have connectivity to the coupling facility
that contains the list structure. Possible reasons for this are: - The operator issued VARY PATH,OFFLINE.
- The operator issued CONFIG CHP,OFFLINE.
- Hardware errors to the coupling facility.
- Facility or path failure to the coupling facility.
Action: Begin rebuilding the structure on a different
coupling facility, or disconnect from the structure.
|
C |
xxxx0C13 |
Equate Symbol: IXLRSNCODEREQPURGED Meaning: Environmental
error. The request was purged prior to completion of the request.
Possible reasons include: - The connector failed.
- The connector disconnected.
- The requestor failed.
- The request was purged by IXLPURGE.
- Requests were purged when the connector provided an IXLEERSP response
for the Rebuild Stop or Rebuild Cleanup event.
- The secondary address space was no longer valid.
Action: None if this is expected. Otherwise,
determine why the connector failed.
|
C |
xxxx0C14 |
Equate Symbol: IXLRSNCODESTATUSUNKNOWN Meaning: Environmental
error. The request has completed, but the final disposition of the
request cannot be determined. The answer area (ANSAREA) fields do
not contain valid information.
Action: - Verify the validity of your data by comparing the expected results
with what is in the coupling facility.
- Consider running rebuild processing to move the structure to attempt
to protect it from further errors of this kind.
|
C |
xxxx0C25 |
Equate Symbol: IXLRSNCODESTRFAILURE Meaning: Environmental
error. The list structure failed prior to completion of the request.
Action: Either
rebuild or disconnect from the structure.
|
C |
xxxx0C68 |
Equate Symbol: IXLRSNCODEBADREQCFLEVEL Meaning: Environmental
error. The request type is not permitted for the level of coupling
facility in which the target structure is allocated.
Action: Either
disconnect from the structure (using IXLDISC) or initiate a rebuild
of the structure, if allowed (using IXLREBLD) in a coupling facility
of the correct CFLEVEL.
|
C |
xxxx0CA0 |
Equate Symbol: IXLRSNCODEQUIESCEDSUSPENDFAIL Meaning: Environmental
error. The request is failed because the structure is quiesced for
a system-managed process and SUSPEND=FAIL is specified on the IXLCONN.
Action: None,
if this is expected.
|
C |
xxxxFFFF |
Equate Symbol: IXLRSNCODENOTAVAILABLE Meaning: Environmental
error. XES functions are not available. This could occur because the
coupling facility hardware necessary to provide XES functions is not
present.
Action: Re-IPL the system, or follow your
particular failure management protocol.
|
10 |
xxxx10xx |
Meaning: System error. XES processing failure. The state
of the involved structure and the disposition of the request are unpredictable.
The answer area (ANSAREA) fields do not contain valid information.
Action: Contact the IBM® support
center.
|