The parameter descriptions are listed in alphabetical order. Default
values are underlined: - CONTOKEN=contoken
- Use this input parameter to specify the connect token you received
when you issued the IXLCONN macro to connect to the cache or list
structure.
To Code: Specify the RS-type name or address
(using a register from 2 to 12) of a 16-character field that contains
the connect token.
- ,MF=S
- ,MF=(L,mfctrl)
- ,MF=(L,mfctrl,mfattr)
- ,MF=(L,mfctrl,0D)
- ,MF=(E,mfctrl)
- ,MF=(E,mfctrl,COMPLETE)
- Use MF=S to specify the standard form of the macro, which builds
an inline parameter list and generates the macro invocation to transfer
control to the service.
Use MF=L to specify the list form of the macro. Use the list form
together with the execute form of the macro for applications that
require reentrant code. The list form defines an area of storage that
the execute form uses to store the parameters. Only the PLISTVER parameter
can be coded with the list form of the macro.
Use MF=E to specify the execute form of the macro. Use the execute
form together with the list form of the macro for applications that
require reentrant code. The execute form stores the parameters into
the storage area defined by the list form, and generates the macro
invocation to transfer control to the service.
- ,mfctrl
- Use this output parameter to specify a storage area to contain
the parameters.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of the parameter list.
- ,mfattr
- Use this input parameter to specify the name of a 1- to 60-character
string that can contain any value that is valid on an assembler DS
pseudo-op. You can use this parameter to force boundary alignment
of the parameter list. If you do not code mfattr, the system
provides a value of 0D, which forces the parameter list to a doubleword
boundary.
- ,COMPLETE
- Use this input parameter to require that the system check for
required parameters and supply defaults for omitted optional parameters.
Note: In the macro expansion you might see some defaults for optional
parameters that are not documented here. The ones that are not documented
do not have any effect on the macro. For example, if SMILE=var were
an optional parameter and the default is SMILE=NO_SMILE then it would
not be documented. However, if the default was SMILE=:-), then it
would be documented because a value would be the default.
- ,OPTYPE=COMPLETE
- ,OPTYPE=TEST
- Use OPTYPE=COMPLETE to request that the IXLFCOMP request return
information only when the list or cache request identified by REQTOKEN
has completed. If the request identified by REQTOKEN has not completed,
your task will be suspended until it has completed.
Use OPTYPE=TEST
to test the current processing status of the list or cache request.
If your task cannot be suspended, use this option to poll for request
completion.
- ,REQTOKEN=reqtoken
- Use this input parameter to specify the asynchronous request token
returned by the IXLLIST or IXLCACHE request. This token identifies
the asynchronous request.
To Code: Specify the RS-type
name or address (using a register from 2 to 12) of a 16-character
field that contains the asynchronous request token.
- ,RETCODE=retcode
- Use this output parameter to specify a field to contain the return
code. (The return code is also returned in register 15.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the return code
when the request has completed.
- ,RSNCODE=rsncode
- Use this output parameter to specify a field to contain the reason
code returned, if applicable. (The reason code is also returned in
register 0.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the reason code
(if any) when the request has completed.
|