z/OS MVS Programming: Sysplex Services Reference
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Output Register Information

z/OS MVS Programming: Sysplex Services Reference
SA38-0658-00

When control returns to the caller of the IXLCONN macro, the general purpose registers (GPRs) contain:
Register
Contents
0
Reason code, if applicable, if GPR 15 return code is nonzero
1
Used as work register by the system
2-13
Unchanged
14
Used as work register by the system
15
Return code
When control returns to the caller of the IXLCONN macro, the access registers (ARs) contain:
Register
Contents
0-1
Used as work registers by the system
2-13
Unchanged
14-15
Used as work registers by the system

Go to the previous page Go to the next page