z/OS MVS Programming: Sysplex Services Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Performing a Write Operation as part of a MOVE Request

z/OS MVS Programming: Sysplex Services Guide
SA23-1400-00

To perform a write operation as part of the move request, specify DATAOPER=WRITE with ENTRYTYPE=OLD or ENTRYTYPE=ANY.
  • Specify ENTRYTYPE=OLD to update the list entry's data entry with the data in the buffer specified by BUFFER or BUFLIST, the adjunct data with the data in the storage area specified by ADJAREA, or both.
  • Specify ENTRYTYPE=ANY to request the following:
    • If the target list entry exists, move it and update it as described for ENTRYTYPE=OLD.
    • If the target list entry does not exist, create a new list entry at the target position, containing the data entry data in the buffer specified by BUFFER or BUFLIST, the adjunct data in the storage specified by ADJAREA, or both.

Go to the previous page Go to the next page