Understanding Rebuild Stop Processing

z/OS MVS Programming: Sysplex Services Guide
SA23-1400-00

The following list summarizes the events for a stop rebuilding request:

  1. Stop rebuilding initiated through a SETXCF operator command or an IXLREBLD macro invocation.
  2. The system reports Rebuild Stop event to the event exit. Connection must issue IXLEERSP to respond to the event.
  3. Connection stops activity to the new structure, performs cleanup, and issues IXLEERSP EVENT=REBLDSTOP.
  4. When all IXLEERSP responses are received, the system reports the Rebuild Stop Process Complete event to the event exit.