21 |
0000 |
The stand-alone dump program is waiting for I/O on the IPL
device. |
None. |
22 |
0000 |
The stand-alone dump program is waiting for intervention on
the IPL device. |
Ready the IPL device. |
24 |
|
The stand-alone dump program detected an error. |
If the dump program did not issue message AMD005I, try a system
restart. If system restart fails, reIPL the stand-alone dump program,
preferably from a different volume. |
|
0100 |
The stand-alone dump program cannot read the volume label. |
Use another volume or regenerate the label. Other data sets
on the volume might be unusable. |
|
0200 |
The volume label is nonstandard. |
Use another volume or regenerate the label. Other data sets
on the volume might be unusable. |
|
0300 |
The stand-alone dump program cannot read the format 4 data
set control block (DSCB). |
Use another volume or change the DSCB. Other data sets on the
volume might be unusable. |
|
0400 |
The system does not support the IPL device type. |
Use a device type that the system supports. |
|
0500 |
The SYS1.PAGEDUMP data set is not on the IPL volume. |
None. |
|
0501 |
A non-format 1 DSCB for SYS1.PAGEDUMP was
found on the IPL volume.
|
None. |
|
0600 |
The stand-alone dump program cannot read the stand-alone dump
common communication table (CCT). |
None. |
|
0700 |
The stand-alone dump program cannot write to
the stand-alone dump file. |
None. |
For a tape IPL version, this could result from a missing write
ring in the IPL volume. |
If tape IPL, check for the needed write ring, or disable file
protection. |
|
0800 |
The stand-alone dump program cannot read module AMDSARDM. |
None. |
|
0900 |
The stand-alone dump program cannot read module AMDSADIP. |
None. |
|
0A00 |
The stand-alone dump program cannot read module AMDSAPGE. |
None. |
25 |
0200 |
A program check or other unexpected error was detected during
output DASD dump data set processing. The system ends the dump. |
None. |
27 |
0010 |
The validity check of the devices and dump options table (DDO)
failed after the system loaded it from SYS1.PAGEDUMP. The system ends
the dump. |
None. |
|
0020 |
The validity check of the dump relocation table (RLT) failed
after the system loaded the AMDSAPGE load module from SYS1.PAGEDUMP.
The system ends the dump. |
None. |
|
0030 |
An error occurred while the system read the AMDSAPGE load module
from SYS1.PAGEDUMP The system ends the dump. |
None. |
|
0040 |
The system detected an internal logic error in the SADMP dump
initialization program. The system ends the dump. |
None. |
28 |
0100 |
The DASD IPL program is unable to read the label on the IPL
device. The system ends the dump. |
None. |
|
0200 |
The DASD IPL program encountered a non-standard label on the
IPL device. The system ends the dump. |
None. |
|
0300 |
The DASD IPL program is unable to read the format 4 data set
control block (DSCB) on the IPL device. The system ends the dump. |
None. |
|
0400 |
The DASD IPL program detected an unsupported device type for
the IPL device. The system ends the dump. |
None. |
|
0500 |
The DASD IPL program could not locate SYS1.PAGEDUMP on the
IPL device. The system ends the dump. |
None. |
|
0600 |
The DASD IPL program could not read the stand-alone dump common
communication table (CCT) from the IPL device. The system ends the
dump. |
None. |
|
0700 |
A permanent I/O error occurred while performing I/O to the
SYS1.PAGEDUMP work file on the DASD IPL device. The system ends the
dump. |
None. |
|
0800 |
A permanent I/O error occurred while performing I/O to the
SYS1.PAGEDUMP work file on the DASD IPL device. The system ends the
dump. |
None. |
|
0900 |
A program check or other unexpected error was encountered in
the DASD IPL module or subroutine. The system ends the dump. |
None. |
|
0A00 |
The work file interface in the DASD IPL module was passed incorrect
parameters. The system ends the dump. |
None. |
|
0B00 |
The DASD IPL program detected an error when performing a Sense-ID
to the IPD device. The system ends the dump. |
None. |
|
0C00 |
The DASD IPL program could not read the DAT validation and
initialization routine (AMDSADVI) from the IPL device. The system
ends the dump. |
None. |
|
0D00 |
The DASD IPL program could not write page 1 to the work file
on the IPL device. The system ends the dump. |
None. |
|
0E00 |
The DASD IPL program could not read the IPL initialization
routine (AMDSAIPI) from the IPL device. The system ends the dump. |
None. |
|
0F00 |
The stand-alone dump program was IPLed from
DASD on a processor which does not support z/Architecture. |
None. |
29 |
0700 |
The tape IPL module was unable to write to the work file on
the IPL tape. The system ends the dump. |
None. |
|
0800 |
The tape IPL module was unable to read the dump program loader
(AMDSADPL) from the IPL tape. The system ends the dump. |
None. |
|
0900 |
A program check or other unexpected error was encountered in
the tape IPL module or subroutine. The system ends the dump. |
None. |
|
0A00 |
The work file interface in the tape IPL module was passed incorrect
parameters. The system ends the dump. |
None. |
|
0C00 |
The tape IPL program could not read the DAT validation and
initialization routine (AMDSADVI). |
None. |
|
0D00 |
The tape IPL program could not write page 1 to the work file
on the IPL device. The system ends the dump. |
None. |
|
0E00 |
The tape IPL program could not read the IPL initialization
routine (AMDSAIPI) from the IPL device. The system ends the dump. |
None. |
|
0F00 |
The stand-alone dump program was IPLed from
tape on a processor which does not support z/Architecture. |
None. |
31 |
dddd |
The stand-alone dump program is waiting for I/O to the device. |
None. |
32 |
dddd |
The stand-alone dump program is waiting for intervention on
the device. |
Mount and ready a tape. |
33 |
0mmm |
The stand-alone dump program is waiting for a reply to message
AMDmmmA or AMDmmmD. |
Reply to the message. |
34 |
dddd |
The stand-alone dump program detected an I/O error on the device
and is waiting for a sense command to complete. |
None. |
35 |
dddd |
The stand-alone dump program restarted I/O on the device and
is waiting for I/O to complete. |
None. |
36 |
0100 |
The output tape is labelled and cannot be used. |
Mount another tape and ready it. |
|
0200 |
The output tape needs a file protect ring. |
Insert a ring into the tape and ready it, or disable file protection. |
|
0300 |
The output tape is full. |
Save the previous tape and mount a new one. |
37 |
0ddd |
The stand-alone dump program is waiting for I/O that is neither
a sense nor a restart to complete on the device. |
None. |
38 |
0000 |
The stand-alone dump program is waiting for
I/O to complete on any of the output devices. |
None. |
3E |
0000 |
The system is waiting for one of the following: - An attention interrupt from the operator selected console
- An interrupt from the system console
- An external key interrupt to indicate a no-console condition.
|
Select the system console or press ENTER on one of the consoles
defined in the AMDSADMP macro. If a console is not available, ready
a tape on the tape drive that you defined on the AMDSADMP macro, then
cause an external interruption. |
|
0100 |
All storage was cleared to binary zeroes prior to the loading
of stand-alone dump. |
None. If SADMP is restarted at this point, a dump will be
produced that contains the central processor status records, a summary
of the cleared storage, and the stand-alone dump message log. |
|
0200 |
The default console was not usable. Either the device specified
in the load parm was not found, or an I/O occurred when trying to
write to the device. |
Select the system console or press ENTER on one of the
consoles defined in the AMDSADMP macro. If a console is not available,
then cause an external interruption to proceed with dumping to the
device you defined on the AMDSADMP macro. |
3F |
0100 |
The generated output device cannot be used, and due to a no-console
condition, a replacement cannot be specified. The system ends the
dump. |
None. |
|
0101 |
The generated output DASD data set is not initialized and REUSEDS=NEVER
was specified on the AMDSADMP macro. Because of a no-console condition,
a replacement cannot be specified. The system ends the dump. |
Do one of the following: - Reinitialize the output data set from another system and perform
a system restart.
- Perform a system restart and select a usable console so that a
different output device can be specified.
|
|
0102 |
The generated output DASD data set is initialized and REUSEDS=CHOICE
was specified on the AMDSADMP macro. Because of a no-console condition,
SADMP cannot issue message AMD096A to determine if the data set should
be reused. |
Do one of the following: - Reinitialize the output data set from another system and perform
a system restart.
- Perform a system restart and select a usable console so that SADMP
can issue AMD096A.
|
|
0200 |
A program check or other unexpected error was detected during
output device initialization. The system ends the dump. |
None. |
40 |
0100 |
The generated output device address is not usable, and due
to a no-console condition, a replacement cannot be specified. The
system ends the dump. |
None. |
|
0200 |
A program check or other unexpected error was detected during
output device address processing. The system ends the dump. |
None. |
41 |
0000 |
The SADMP program ended normally; dumping is complete. Note: Message
AMD104I can be an indication of successful completion of dump.
|
Save the dump. |
47 |
0000 |
An unexpected machine check occurred. |
Record the wait state code. If necessary, rewind and unload
the output tape; the normal end-of-file is not present. |
|
0001 |
An unrecoverable machine check with invalid registers occurred. |
Record the wait state code. If necessary, rewind and unload
the output tape; the normal end-of-file is not present. |
4F |
ssee |
The virtual storage dump program ended due to an internal error. - ss denotes the failing module or service.
- ee denotes the specific type of error.
Common codes are listed below. The stand-alone dump program
tries to write a self-dump to the output device. Message AMD066I also
contains these wait reason codes. |
Record the wait state code. If necessary, rewind and unload
the output tape; the normal end-of-file is not present. |
|
0D01 |
An unexpected error occurred during SADMP error recovery and
program ending processing. |
None. |
|
0D02 |
The stand-alone dump program requested too many self-dumps. |
None. |
|
0D03 |
The system ended SADMP error recovery and program ending processing
because of I/O errors. |
None. |
|
0D05 |
The system did not find any SADMP error recovery module on
the recovery stack. |
None. |
|
0E10 |
The system cannot continue processing because there are not
enough SADMP internal storage blocks (BCT) on the available queue. |
None. |
|
0F01 |
A permanent I/O error occurred on the output DASD and the operator
replied 'T' to message AMD098A. |
Perform a system restart to dump to another output device. |
|
13F1 |
A permanent I/O error occurred on the output tape and the operator
replied 'T' to message AMD098A. |
Perform a system restart to dump to another output device. |
|
14F1 |
A permanent I/O error occurred on the output tape, and the
operator replied ‘T’ to message AMD098A. |
Perform a system restart to dump to another output device. |
|
1C13 |
A system restart occurred. |
None. |
|
1D12 |
An external interruption occurred. |
None. |
|
1E20 |
The operator replied ‘T’ to message AMD088D. |
None. |
|
1E30 |
The prefix storage area (PSA) was incorrect. The system cannot
dump virtual storage. |
None. |
|
1E40 |
The segment table (SGT) was incorrect. The system cannot dump
virtual storage. |
None. |
|
1E50 |
The page table (PGT) was incorrect. The system cannot dump
virtual storage. |
None. |
|
1E60 |
The communication vector table (CVT) was incorrect. The system
cannot dump virtual storage. |
None. |
|
1E70 |
The paging vector table (PVT) was incorrect. The system cannot
dump virtual storage. |
None. |
|
1E80 |
The real storage manager (RSM) internal table (RIT) was incorrect.
The system cannot dump virtual storage. |
None. |
|
1E90 |
The page frame table (PFT) was incorrect. The system cannot
dump virtual storage. |
None. |
|
1EA0 |
No contiguous storage could be found for a swap SGT. The system
could not dump virtual storage. |
None. |
|
22F1 |
A permanent I/O error occurred on the output tape volume and
the operator replied 'T' to message AMD098A. |
Perform a system restart to dump to another output device. |
|
4701 |
A program check or other unexpected error was detected during
dump title processing. The system ends the dump. |
None. |
|
ssF1 |
An I/O error occurred on the output device. |
Perform a system restart to dump to another output device. |
|
FEcc |
A program check occurred. cc is the rightmost
byte of the program interruption code. |
None. |
52 |
0200 |
The IPL initialization routine found a non-standard label on
the IPL device. The system ends the dump. |
None. |
|
0400 |
The IPL initialization routine found the IPL device to be an
unsupported device. The system ends the dump. |
None. |
|
0500 |
The IPL initialization routine was unable to locate the SYS1.PAGEDUMP.Vvolser
on the IPL device. The system ends the dump. |
None. |
|
0F00 |
The stand-alone dump program was IPLed on a processor which
does not support z/Architecture. |
None. |