z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Stand-alone dump wait state codes

z/OS MVS System Codes
SA38-0665-00

When producing a stand-alone dump, a stand-alone dump program loads wait state codes into the PSW to tell the operator about certain problems.

In z/Architecture® mode, the PSW for one of these wait states has the format:
X'00020000 00000000 00000000 00wwrrrr'
2
Bits 12-15 (the CMWP bits).
ww
The hexadecimal wait state code.
rrrr
The hexadecimal reason code.
Table 1. Stand-alone dump wait state codes
Wait state code Reason code Explanation Operator response
21 0000 The stand-alone dump program is waiting for I/O on the IPL device. None.
22 0000 The stand-alone dump program is waiting for intervention on the IPL device. Ready the IPL device.
24   The stand-alone dump program detected an error. If the dump program did not issue message AMD005I, try a system restart. If system restart fails, reIPL the stand-alone dump program, preferably from a different volume.
  0100 The stand-alone dump program cannot read the volume label. Use another volume or regenerate the label. Other data sets on the volume might be unusable.
  0200 The volume label is nonstandard. Use another volume or regenerate the label. Other data sets on the volume might be unusable.
  0300 The stand-alone dump program cannot read the format 4 data set control block (DSCB). Use another volume or change the DSCB. Other data sets on the volume might be unusable.
  0400 The system does not support the IPL device type. Use a device type that the system supports.
  0500 The SYS1.PAGEDUMP data set is not on the IPL volume. None.
  0501

A non-format 1 DSCB for SYS1.PAGEDUMP was found on the IPL volume.

None.
  0600 The stand-alone dump program cannot read the stand-alone dump common communication table (CCT). None.
  0700 The stand-alone dump program cannot write to the stand-alone dump file. None.
For a tape IPL version, this could result from a missing write ring in the IPL volume. If tape IPL, check for the needed write ring, or disable file protection.
  0800 The stand-alone dump program cannot read module AMDSARDM. None.
  0900 The stand-alone dump program cannot read module AMDSADIP. None.
  0A00 The stand-alone dump program cannot read module AMDSAPGE. None.
25 0200 A program check or other unexpected error was detected during output DASD dump data set processing. The system ends the dump. None.
27 0010 The validity check of the devices and dump options table (DDO) failed after the system loaded it from SYS1.PAGEDUMP. The system ends the dump. None.
  0020 The validity check of the dump relocation table (RLT) failed after the system loaded the AMDSAPGE load module from SYS1.PAGEDUMP. The system ends the dump. None.
  0030 An error occurred while the system read the AMDSAPGE load module from SYS1.PAGEDUMP The system ends the dump. None.
  0040 The system detected an internal logic error in the SADMP dump initialization program. The system ends the dump. None.
28 0100 The DASD IPL program is unable to read the label on the IPL device. The system ends the dump. None.
  0200 The DASD IPL program encountered a non-standard label on the IPL device. The system ends the dump. None.
  0300 The DASD IPL program is unable to read the format 4 data set control block (DSCB) on the IPL device. The system ends the dump. None.
  0400 The DASD IPL program detected an unsupported device type for the IPL device. The system ends the dump. None.
  0500 The DASD IPL program could not locate SYS1.PAGEDUMP on the IPL device. The system ends the dump. None.
  0600 The DASD IPL program could not read the stand-alone dump common communication table (CCT) from the IPL device. The system ends the dump. None.
  0700 A permanent I/O error occurred while performing I/O to the SYS1.PAGEDUMP work file on the DASD IPL device. The system ends the dump. None.
  0800 A permanent I/O error occurred while performing I/O to the SYS1.PAGEDUMP work file on the DASD IPL device. The system ends the dump. None.
  0900 A program check or other unexpected error was encountered in the DASD IPL module or subroutine. The system ends the dump. None.
  0A00 The work file interface in the DASD IPL module was passed incorrect parameters. The system ends the dump. None.
  0B00 The DASD IPL program detected an error when performing a Sense-ID to the IPD device. The system ends the dump. None.
  0C00 The DASD IPL program could not read the DAT validation and initialization routine (AMDSADVI) from the IPL device. The system ends the dump. None.
  0D00 The DASD IPL program could not write page 1 to the work file on the IPL device. The system ends the dump. None.
  0E00 The DASD IPL program could not read the IPL initialization routine (AMDSAIPI) from the IPL device. The system ends the dump. None.
  0F00 The stand-alone dump program was IPLed from DASD on a processor which does not support z/Architecture. None.
29 0700 The tape IPL module was unable to write to the work file on the IPL tape. The system ends the dump. None.
  0800 The tape IPL module was unable to read the dump program loader (AMDSADPL) from the IPL tape. The system ends the dump. None.
  0900 A program check or other unexpected error was encountered in the tape IPL module or subroutine. The system ends the dump. None.
  0A00 The work file interface in the tape IPL module was passed incorrect parameters. The system ends the dump. None.
  0C00 The tape IPL program could not read the DAT validation and initialization routine (AMDSADVI). None.
  0D00 The tape IPL program could not write page 1 to the work file on the IPL device. The system ends the dump. None.
  0E00 The tape IPL program could not read the IPL initialization routine (AMDSAIPI) from the IPL device. The system ends the dump. None.
  0F00 The stand-alone dump program was IPLed from tape on a processor which does not support z/Architecture. None.
31 dddd The stand-alone dump program is waiting for I/O to the device. None.
32 dddd The stand-alone dump program is waiting for intervention on the device. Mount and ready a tape.
33 0mmm The stand-alone dump program is waiting for a reply to message AMDmmmA or AMDmmmD. Reply to the message.
34 dddd The stand-alone dump program detected an I/O error on the device and is waiting for a sense command to complete. None.
35 dddd The stand-alone dump program restarted I/O on the device and is waiting for I/O to complete. None.
36 0100 The output tape is labelled and cannot be used. Mount another tape and ready it.
  0200 The output tape needs a file protect ring. Insert a ring into the tape and ready it, or disable file protection.
  0300 The output tape is full. Save the previous tape and mount a new one.
37 0ddd The stand-alone dump program is waiting for I/O that is neither a sense nor a restart to complete on the device. None.
38 0000 The stand-alone dump program is waiting for I/O to complete on any of the output devices. None.
3E 0000 The system is waiting for one of the following:
  • An attention interrupt from the operator selected console
  • An interrupt from the system console
  • An external key interrupt to indicate a no-console condition.
Select the system console or press ENTER on one of the consoles defined in the AMDSADMP macro. If a console is not available, ready a tape on the tape drive that you defined on the AMDSADMP macro, then cause an external interruption.
  0100 All storage was cleared to binary zeroes prior to the loading of stand-alone dump. None. If SADMP is restarted at this point, a dump will be produced that contains the central processor status records, a summary of the cleared storage, and the stand-alone dump message log.
  0200 The default console was not usable. Either the device specified in the load parm was not found, or an I/O occurred when trying to write to the device. Select the system console or press ENTER on one of the consoles defined in the AMDSADMP macro. If a console is not available, then cause an external interruption to proceed with dumping to the device you defined on the AMDSADMP macro.
3F 0100 The generated output device cannot be used, and due to a no-console condition, a replacement cannot be specified. The system ends the dump. None.
  0101 The generated output DASD data set is not initialized and REUSEDS=NEVER was specified on the AMDSADMP macro. Because of a no-console condition, a replacement cannot be specified. The system ends the dump. Do one of the following:
  • Reinitialize the output data set from another system and perform a system restart.
  • Perform a system restart and select a usable console so that a different output device can be specified.
  0102 The generated output DASD data set is initialized and REUSEDS=CHOICE was specified on the AMDSADMP macro. Because of a no-console condition, SADMP cannot issue message AMD096A to determine if the data set should be reused. Do one of the following:
  • Reinitialize the output data set from another system and perform a system restart.
  • Perform a system restart and select a usable console so that SADMP can issue AMD096A.
  0200 A program check or other unexpected error was detected during output device initialization. The system ends the dump. None.
40 0100 The generated output device address is not usable, and due to a no-console condition, a replacement cannot be specified. The system ends the dump. None.
  0200 A program check or other unexpected error was detected during output device address processing. The system ends the dump. None.
41 0000 The SADMP program ended normally; dumping is complete.
Note: Message AMD104I can be an indication of successful completion of dump.
Save the dump.
47 0000 An unexpected machine check occurred. Record the wait state code. If necessary, rewind and unload the output tape; the normal end-of-file is not present.
  0001 An unrecoverable machine check with invalid registers occurred. Record the wait state code. If necessary, rewind and unload the output tape; the normal end-of-file is not present.
4F ssee The virtual storage dump program ended due to an internal error.
  • ss denotes the failing module or service.
  • ee denotes the specific type of error.
Common codes are listed below. The stand-alone dump program tries to write a self-dump to the output device. Message AMD066I also contains these wait reason codes.
Record the wait state code. If necessary, rewind and unload the output tape; the normal end-of-file is not present.
  0D01 An unexpected error occurred during SADMP error recovery and program ending processing. None.
  0D02 The stand-alone dump program requested too many self-dumps. None.
  0D03 The system ended SADMP error recovery and program ending processing because of I/O errors. None.
  0D05 The system did not find any SADMP error recovery module on the recovery stack. None.
  0E10 The system cannot continue processing because there are not enough SADMP internal storage blocks (BCT) on the available queue. None.
  0F01 A permanent I/O error occurred on the output DASD and the operator replied 'T' to message AMD098A. Perform a system restart to dump to another output device.
  13F1 A permanent I/O error occurred on the output tape and the operator replied 'T' to message AMD098A. Perform a system restart to dump to another output device.
  14F1 A permanent I/O error occurred on the output tape, and the operator replied ‘T’ to message AMD098A. Perform a system restart to dump to another output device.
  1C13 A system restart occurred. None.
  1D12 An external interruption occurred. None.
  1E20 The operator replied ‘T’ to message AMD088D. None.
  1E30 The prefix storage area (PSA) was incorrect. The system cannot dump virtual storage. None.
  1E40 The segment table (SGT) was incorrect. The system cannot dump virtual storage. None.
  1E50 The page table (PGT) was incorrect. The system cannot dump virtual storage. None.
  1E60 The communication vector table (CVT) was incorrect. The system cannot dump virtual storage. None.
  1E70 The paging vector table (PVT) was incorrect. The system cannot dump virtual storage. None.
  1E80 The real storage manager (RSM) internal table (RIT) was incorrect. The system cannot dump virtual storage. None.
  1E90 The page frame table (PFT) was incorrect. The system cannot dump virtual storage. None.
  1EA0 No contiguous storage could be found for a swap SGT. The system could not dump virtual storage. None.
  22F1 A permanent I/O error occurred on the output tape volume and the operator replied 'T' to message AMD098A. Perform a system restart to dump to another output device.
  4701 A program check or other unexpected error was detected during dump title processing. The system ends the dump. None.
  ssF1 An I/O error occurred on the output device. Perform a system restart to dump to another output device.
  FEcc A program check occurred. cc is the rightmost byte of the program interruption code. None.
52 0200 The IPL initialization routine found a non-standard label on the IPL device. The system ends the dump. None.
  0400 The IPL initialization routine found the IPL device to be an unsupported device. The system ends the dump. None.
  0500 The IPL initialization routine was unable to locate the SYS1.PAGEDUMP.Vvolser on the IPL device. The system ends the dump. None.
  0F00 The stand-alone dump program was IPLed on a processor which does not support z/Architecture. None.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014