Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
47D z/OS MVS System Codes SA38-0665-00 |
|
47D ExplanationDuring processing of an EVENTS macro, the system found that the address specified on the LAST parameter was incorrect. LAST must specify an address between the first and last valid entries in the EVENTS table. System actionThe system abnormally ends the program that issued the EVENTS macro. System programmer responseIf the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the program listing and the assembly listing associated with the job. Programmer responseEnsure that the LAST address is a valid table entry that has not been previously purged from the EVENTS table. Correct the error. Run the job again. SourceTask management |