20E z/OS MVS System Codes SA38-0665-00 |
|
20E ExplanationA program issued a SPIE macro that specified an incorrect address for the SPIE program interruption element (PIE). System actionThe system sends messages about the problem to the job log. The system abends the program that issued the SPIE macro. Operator responseIf the system programmer asks for an SVC dump,
set the following SLIP trap:
System programmer responseIf an IBM® program
issued the macro, search problem reporting data bases for a fix for
the problem. If no fix exists, contact the IBM Support Center. Provide:
Programmer responseIf an application program issued the incorrect macro, correct the PIE address, ensuring that it is a valid virtual storage address assigned to the job step. Rerun the job. SourceRecovery termination manager (RTM) |