z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


1FC

z/OS MVS System Codes
SA38-0665-00

1FC

Explanation

In response to a Supervisor Call (SVC) instruction, the SVC first level interrupt handler (FLIH) was running, but a system error occurred.

System action

In an attempt to recover, the system abnormally ends the task that issued the SVC instruction. The system writes a logrec data set error record.

Operator response

If the system programmer asks for an SVC dump, set the following SLIP trap:
SLIP SET,COMP=1FC,ACTION=SVCD,END

System programmer response

Do the following:
  1. Find the original abend causing the problem in the system diagnostic work area (SDWA) in the logrec data set error record for abend X'1FC'.
  2. Search problem reporting data bases for a fix for the problem. If no fix exists, ask the operator to set a SLIP trap to obtain an SVC dump. Contact the IBM® Support Center. Provide the SVC dump and, if available, the logrec data set error record.

Source

Supervisor control

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014