z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


177

z/OS MVS System Codes
SA38-0665-00

177

Explanation

During processing of a TESTAUTH macro, the system detected incorrect input parameters, as follows:
  • An incorrect bit mask is in register 1.
  • RBLEVEL=2, but the request block (RB) is the last RB chained or is out of range.
  • The function code is greater than 256 or is out of range.
  • The authorization code is greater than 256 or is out of range.

System action

The system abnormally ends the program that issued the TESTAUTH macro.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the program listing for the job.

Programmer response

Ensure that the TESTAUTH parameter list is valid. The only valid IBM-supplied authorization or function code is one (1). If the installation supplied an authorization matrix, check to see that the function and authorization codes fall within the range of the installation-defined codes.

Source

Task management

Go to the previous page Go to the next page