z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


144

z/OS MVS System Codes
SA38-0665-00

144

Explanation

The error occurred during the processing of SYNADAF, where it was determined that an incorrect access method code was specified in the high order byte of register 15.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the JCL and the program listing for the job.

Programmer response

Make sure that the ACSMETH parameter on the SYNADAF macro instruction is correctly coded, or that the high order byte of register 15 contains a valid access method code before issuing SVC 68.

Source

DFSMSdfp

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014