z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


0F6

z/OS MVS System Codes
SA38-0665-00

0F6

Explanation

During processing of a SETEVENT macro for the generalized trace facility (GTF), an error occurred. Register 15 contains a hexadecimal reason code that explains the error:
Code
Explanation
00
The issuer of the SETEVENT macro was not authorized through the authorized program facility (APF), was not in protect key 0-7, or was not in supervisor state.
04
The parameter list passed to SETEVENT was incorrect.
08
An incorrect address for the monitor call queue element (MCQE) was passed to SETEVENT.
0C
The MCQE at the address passed to SETEVENT is incorrect for the function requested.
20
The call to SETEVENT:
  • Attempted to add elements to an existing event directory
  • Would have resulted in multiple MCQEs.

System action

The system writes messages and a dump.

System programmer response

If an installation-provided program issued the SETEVENT, ensure that the program is authorized. Correct the error indicated by the reason code. Run the job again.

If an IBM-provided program issued the SETEVENT, collect all printed output and output data sets related to the problem. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output and the dump for the job.

Source

Generalized trace facility (GTF)

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014