z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


0E8

z/OS MVS System Codes
SA38-0665-00

0E8

Explanation

The error occurred while processing the VIO data sets for the job after an abnormal system or job step task failure. Register 15 contains one of the following hexadecimal reason codes:
Code
Explanation
3xx
ASM was unable to release the logical group for this data set. See code 0E4 for an explanation of xx.

System action

The input parm list (RMPL) and the ASCB are dumped to the SYS1.DUMP data set.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output for the job and the logrec data set error record.

Programmer response

System error. Rerun the job.

Source

DFSMSdfp

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014