0E4

z/OS MVS System Codes
SA38-0665-00

0E4

Explanation

The error occurred while trying to scratch a VIO data set.

Register 15 contains one of the following hexadecimal reason codes:
Code
Explanation
3xx
ASM could not RELEASE the logical group for this data set. Where xx is:
xx
Explanation
04
Incorrect LGN.
1C
Unable to obtain storage to process request.
20
Incorrect operation code is supplied in the auxiliary storage manager control area (ACA).
28
Incorrect identifier type when an LGN was given, but ‘S’ type symbol is required.

System action

The DSPCT header is dumped to the SYS1.DUMPxx data set.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output for the job and the logrec data set error record.

Programmer response

System error. Rerun the job.

Source

DFSMSdfp