Explanation
The error occurred during processing of the FE
Common Write (COMWRITE) task. The COMWRITE task has been ended.
The
hexadecimal contents of register 3 indicates the nature of the error:
- Register 3
- Explanation
- 01
- Permanent I/O error on output device. Register 7 contains user
ID; register 8 contains address of failing DECB.
- 02
- STAE routine failed. Register 15 contains the return code.
- 03
- User parameter list is incorrect, and output required was specified.
Register 7 contains the address of the parameter list saved in COMWRITE.
Register 11 contains the address of the error message.
- 05
- The output DCB failed to open.
- 06
- For one of the traces specified, the size of one half of the trace
table is larger than the maximum block size specified for the trace
data set.
Programmer response
Response depends upon the hexadecimal contents
of register 3:
- Register 3
- Response
- 01
- Check the status of the recording medium. If it is valid, call
your hardware support personnel.
- 02
- Call your hardware support personnel.
- 03
- Check the parameter list.
- 05
- Missing DD statement. Include the DD statement and rerun the job.
- 06
- Ensure that the size of one half of the trace table does not exceed
the maximum block size specified for the trace data set.
Source