z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


044

z/OS MVS System Codes
SA38-0665-00

044

Explanation

The error occurred during processing of the FE Common Write (COMWRITE) task. The COMWRITE task has been ended.

The hexadecimal contents of register 3 indicates the nature of the error:
Register 3
Explanation
01
Permanent I/O error on output device. Register 7 contains user ID; register 8 contains address of failing DECB.
02
STAE routine failed. Register 15 contains the return code.
03
User parameter list is incorrect, and output required was specified. Register 7 contains the address of the parameter list saved in COMWRITE. Register 11 contains the address of the error message.
05
The output DCB failed to open.
06
For one of the traces specified, the size of one half of the trace table is larger than the maximum block size specified for the trace data set.

Programmer response

Response depends upon the hexadecimal contents of register 3:
Register 3
Response
01
Check the status of the recording medium. If it is valid, call your hardware support personnel.
02
Call your hardware support personnel.
03
Check the parameter list.
05
Missing DD statement. Include the DD statement and rerun the job.
06
Ensure that the size of one half of the trace table does not exceed the maximum block size specified for the trace data set.