- Code
- Explanation
- 000A1000
- The activation of a logical unit failed because the VTAM® application for the logical unit is not
APPC-capable. Check the VTAM APPL
statement for the logical unit to ensure that you specified APPC=YES.
System
Action: The system also issues abend X'EC7' with reason
code X'000A0037', which can be ignored.
- 000100xx
- An internal error occurred.
System Action: The system
continues processing, but the requested APPC/MVS service fails. The
system writes an SVC dump.
- 00020001
- A program called the Cleanup_AS service, but either did not provide
the correct number of parameters or did not follow VLIST conventions.
System
Action: The system continues processing, but the requested APPC/MVS
service fails.
- 00020002
- A program called the Cleanup_TP service but either did not provide
the correct number of parameters or did not follow VLIST conventions.
System
Action: The system continues processing, but the requested APPC/MVS
service fails.
- 00020003 - 00020006
- An internal error occurred.
System Action: The system
continues processing, but APPC/MVS initialization fails.
- 00020007
- A program called the unauthorized Cleanup_TP service but either
did not provide the correct number of parameters or did not follow
VLIST conventions.
System Action: The system continues
processing, but the requested APPC/MVS service fails.
- 00020008
- A program issued a version of the Cleanup_Address_Space service
that is not valid on the release of MVS™ installed
on the system.
System Action: The system continues processing,
but the requested APPC/MVS service fails.
- 00020009
- A program called a version of the unauthorized Cleanup_TP service
that is not valid on the release of MVS installed
on the system.
System Action: The system continues processing,
but the requested APPC/MVS service fails.
- 0002000A
- A program called the ATBCUC1 service, which is not valid on the
release of MVS installed on the
system.
System Action: The system continues processing,
but the requested APPC/MVS service fails.
- 0002000B
- An abend occurred when the system tried to access the input parameters
for a callable service. The caller of the program does not have read
or write access to the parameters.
- 00030001
- An internal error occurred while the DISPLAY APPC command processor
was trying to extract data for display.
System Action:
The system ends the DISPLAY command but APPC continues processing.
- 00050001
- A system error occurred during conversion of a transaction program
(TP) profile.
System Action: The system does not use the
TP profile.
- 00050002
- An internal error occurred.
System Action: The system
does not use the TP profile.
- 00050300 - 000503E0
- An internal error occurred during VSAM processing.
System
Action: The system continues processing, but the requested APPC/MVS
service fails.
- 00050420 - 00050424
- A system error occurred during transaction program (TP) profile
processing.
System Action: The system does not use the
TP profile.
- 00050800 - 00050822
- An internal error occurred during TP profile or side information
processing.
System Action: The system continues processing,
but the requested APPC/MVS service fails.
- 00050200
- An internal error occurred during APPC initialization
System
Action: The system continues processing, but APPC/MVS initialization
fails.
- 00050602 - 00050657
- An internal error occurred during TP profile or side information
processing.
- 00060001 - 00060004
- An internal error occurred.
System Action: The system
abnormally ends APPC. If the restart criteria are met, APPC restarts
in a new address space.
- 00060005 - 00060009
- An internal error occurred.
System Action: APPC continues
processing, but inbound processing could be affected.
- 0006000A
- An internal error occurred.
System Action: The system
abnormally ends APPC. If the restart criteria are met, APPC restarts
in a new address space.
- 0006000B
- An internal error occurred.
System Action: APPC continues
processing, but inbound processing could be affected.
- 0006000C - 0006000E
- An internal error occurred.
System Action: The system
abnormally ends APPC. If the restart criteria are met, APPC restarts
in a new address space.
- 0006000F - 00060014
- An internal error occurred.
System Action: APPC continues
processing, but inbound processing could be affected.
- 00070001 - 00070002
- An internal error occurred.
System Action: The system
sends messages to the operator console to show APPC's status following
the abend. If restart conditions are met, APPC will restart itself
in another address space.
- 00070003
- Initialization of the APPC/cross-system coupling facility (XCF)
group name failed.
System Action: The system continues
processing, but APPC resources are not available. If the operator
enters the START APPC command in response to this problem. APPC initialization
will fail.
- 00070004
- The system failed to initialize the APPC/XCF group name. The system
could not find a match for CVTSNAME in the system information returned
from the IXCQUERY macro. The system has not initialized the APPC/XCF
group name.
System Action: The system continues processing,
but APPC resources are not available. If the operator enters the START
APPC command in response to this problem. APPC initialization will
fail.
- 00070005
- An unauthorized attempt was made to start APPC. APPC can only
be invoked by the installation as a started task using the START APPC
command.
System Action: The system sends messages to the
operator console to show APPC's status following the abend. If restart
conditions are met, APPC will restart itself in another address space.
- 00070006
- APPC was unable to obtain required common storage. Register 2
contains the return code from the system STORAGE macro.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 00070008
- An illegal state transition was requested for APPC.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 00070009
- APPC was unable to obtain required private storage. Register 2
contains the return code from the system STORAGE macro.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 0007000A
- An internal error occurred.
System Action: The system
sends messages to the operator console to show APPC's status following
the abend. If restart conditions are met, APPC will restart itself
in another address space.
- 0007000B
- An illegal state transition was requested for one of APPC's divisions.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 0007000C
- The system cannot load the ATBINPVT load module.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 0007000D - 0007000E
- An internal error occurred.
System Action: The system
sends messages to the operator console to show APPC's status following
the abend. If restart conditions are met, APPC will restart itself
in another address space.
- 0007000F
- An initialization error occurred. The system was unable to obtain
an APPC resource.
System Action: The system continues processing,
but the error will cause the failure of APPC initialization processing
if the operator enters a START APPC command.
- 00070010
- An internal error occurred.
System Action: The system
sends messages to the operator console to show APPC's status following
the abend. If restart conditions are met, APPC will restart itself
in another address space.
- 00070011
- The system was unable to load the ATBINPVT load module. Register
2 contains the return code from the system LOAD macro.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 00070012
- The system was unable to load the ATBINLPA load module. Register
2 contains the return code from the system LOAD macro.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 00070013
- The system was unable to load the ATBINMIG load module. Register
2 contains the return code from the system LOAD macro.
System
Action: The system sends messages to the operator console to
show APPC's status following the abend. If restart conditions are
met, APPC will restart itself in another address space.
- 00070015
- An attempt was made to update the state of a division, but the
division identifier is not defined.
System Action: The
system sends messages to the operator console to show APPC's status
following the abend. If restart conditions are met, APPC will restart
itself in another address space.
- 00070019 - 0007001D
- An internal error occurred.
System Action: APPC cannot
restart itself in another address space. APPC services remain unavailable.
- 00090001
- The caller specified a parameter list that contained too many
or too few parameters for the service being invoked,
System
Action: The system denies the request. No conversations end as
a result of the error, unless it results in the abnormal ending of
the address space. If the address space abnormally ends, all conversations
owned by the address space will be cleaned up as part of normal APPC
processing.
- 00090002
- An abend occurred while the system tried to access one of the
following:
- Input parameters to which the caller does not have read access.
- Output parameters to which the caller does not have write access.
- 00090003 - 00090051
- An internal error occurred.
- 00090052
- An internal error occurred.
System Action: The system
continues processing, but the requested APPC/MVS service fails. The
system issues an SVC dump.
- 00090054
- APPC/MVS cannot access the conversation_ID parameter for the Error_Extract
service.
System Action: The system does not process the
call to Error_Extract. The system continues other processing.
- 00090055
- APPC/MVS cannot access the service_name parameter for the Error_Extract
service.
System Action: The system does not process the
call to Error_Extract. The system continues other processing.
- 00090056
- APPC/MVS cannot access the service_reason_code parameter for the
Error_Extract service.
System Action: The system does not
process the call to Error_Extract. The system continues other processing.
- 00090057
- APPC/MVS cannot access the message_text_length parameter for the
Error_Extract service.
System Action: The system does not
process the call to Error_Extract. The system continues other processing.
- 00090058
- APPC/MVS cannot access the message_text parameter for the Error_Extract
service.
System Action: The system does not process the
call to Error_Extract. The system continues other processing.
- 00090059
- APPC/MVS cannot access the error_log_product_set_ID_length parameter
for the Error_Extract service.
System Action: The system
does not process the call to Error_Extract. The system continues
other processing.
- 00090060
- APPC/MVS cannot access the error_log_product_set_ID parameter
for the Error_Extract service.
System Action: The system
does not process the call to Error_Extract. The system continues
other processing.
- 00090061
- APPC/MVS cannot access the error_log_data_length parameter for
the Error_Extract service.
System Action: The system does
not process the call to Error_Extract. The system continues other
processing.
- 00090062
- APPC/MVS cannot access the error_log_data parameter for the Error_Extract
service.
System Action: The system does not process the
call to Error_Extract. The system continues other processing.
- 00090063
- APPC/MVS cannot access the return_code parameter for the Error_Extract
service.
System Action: The system does not process the
call to Error_Extract. The system continues other processing.
- 00090064
- APPC/MVS cannot access the reason_code parameter for the Error_Extract
service.
System Action: The system does not process the
call to Error_Extract. The system continues other processing.
- 00090065
- A program specified an incorrect number of parameters on a call
to Error_Extract.
System Action: The system does not process
the call to Error_Extract. The system continues other processing.
- 00090066 - 00090068
- An internal error occurred in APPC/MVS.
System Action:
The system does not process the call to Error_Extract. The system
continues other processing.
- 00090069
- APPC/MVS cannot access the parameter list for the Error_Extract
service.
System Action: The system does not process the
call to Error_Extract. The system continues other processing.
- 00090070 - 00090073
- An internal error occurred in APPC/MVS.
System Action: The
system continues processing, but the requested APPC/MVS service fails.
The system takes an SVC dump.
- 000A00xx
- An internal error occurred.
System Action: APPC continues
processing.
- 000A1000
- The activation of a logical unit failed because the VTAM application for the logical unit is not
APPC-capable. Check the VTAM APPL
statement for the logical unit to ensure that you specified APPC=YES.
- 00100003
- The join group service abnormally ended while trying to access
the XCFMSGIN_EXIT_ADDRESS input parameter.
System Action:
The system rejects the request. The system does not join the caller
to the APPC group.
- 00100004
- The join group service abnormally ended while trying to access
the XCFMSGIN_MEMDATA input parameter.
System Action: The
system rejects the request. The system does not join the caller to
the APPC group.
- 00100005
- The join group service abnormally ended while trying to access
the XCF_RETURN_CODE input parameter.
System Action: The
system rejects the request. The system does not join the caller to
the APPC group.
- 00100006
- The join group service abnormally ended while trying to access
the XCF_REASON_CODE input parameter.
System Action: The
system rejects the request. The system does not join the caller to
the APPC group.
- 00100007
- The join group service abnormally ended while trying to access
the RETURN_CODE input parameter.
System Action: The system
rejects the request. The system does not join the caller to the APPC
group.
- 00100008
- The join group service abnormally ended while trying to access
the MEMBER_TOKEN input parameter.
System Action: The system
rejects the request. The system does not join the caller to the APPC
group.
- 00100009
- An incorrect number of parameters was passed to the join group
service.
System Action: The system rejects the request.
The system does not join the caller to the APPC group.
- 0010000A - 0010000B
- An internal error occurred.
System Action: The system
automatically restarts APPC. If a second failure occurs, APPC will
abnormally end.
- 0010000C
- The parameter list passed to the Associate Service contained an
incorrect number of parameters.
System Action: APPC continues
processing, but the system does not perform the requested service.
- 0010000D
- The parameter list passed to the Connect Service contained an
incorrect number of parameters.
System Action: APPC continues
processing, but the system does not perform the requested service.
- 0010000E
- The parameter list passed to the Control Service contained an
incorrect number of parameters.
System Action: APPC continues
processing, but the system does not perform the requested service.
- 0010000F
- The parameter list passed to the Disconnect Service contained
an incorrect number of parameters.
System Action: APPC
continues processing, but the system does not perform the requested
service.
- 00100010
- The parameter list passed to the Identify Service contained an
incorrect number of parameters.
System Action: APPC continues
processing, but the system does not perform the requested service.
- 00100011
- The parameter list passed to the Unidentify Service contained
an incorrect number of parameters.
System Action: APPC
continues processing, but the system does not perform the requested
service.
- 00100012
- The parameter list passed to the Define Local TP Service contained
an incorrect number of parameters.
System Action: APPC
continues processing, but the system does not perform the requested
service.
- 00100013
- The parameter list passed to a transaction scheduler interface
service contains inaccessible parameters.
System Action:
APPC continues processing, but the system does not perform the requested
service.
- 00100014
- The join service failed while trying to access the parameter pointers.
The parameter list is inaccessible.
System Action: The
system rejects the request. The system does not join the caller to
the APPC group.
- 00100015
- The parameter list passed to the Set_AS_Attributes service contained
an incorrect number of parameters.
System Action: The system
continues processing, but the requested APPC/MVS service fails.
- 00100016
- The parameter list passed to the Set_AS_Attributes service contains
inaccessible parameters.
- 00100017 - 00100018
- An internal error occurred.
System Action: The system
automatically restarts APPC. If a second failure occurs, APPC abnormally
abends.
- 00100019
- An internal error occurred.
System Action: The callers
task is ended.
- 0010001F
- A program issued a version of the Identify service that is not
valid on the release of MVS installed
on the system.
System Action: The system continues processing,
but the requested APPC/MVS service fails.
- 00100020
- A program issued a version of the Unidentify service that is not
valid on the release of MVS installed
on the system.
System Action: The system continues processing,
but the requested APPC/MVS service fails.
- 00100023
- A program issued a version of the Join_Sysappc_Group service that
is not valid on the release of MVS installed
on the system.
System Action: The system continues processing,
but the requested APPC/MVS service fails.
- 00100025
- A program passed a parameter list containing an incorrect number
of parameters to the Version_Service.
- 00100026
- A program passed an inaccessible parameter list to the Version_Service.
- 00100027
- A program passed a parameter list containing inaccessible parameters
to the Version_Service.
System Action: The system continues
processing, but the requested APPC/MVS service fails.
- 00100028
- An internal error occurred during processing of the Identify service.
System
Action: The system ends the caller's task.
- 00100029
- An internal error occurred during processing of the Unidentify
service.
System Action: The system ends the caller's task.
- 00120001
- The Accept_Test service abnormally ended because the caller's
parameter list was incorrect.
- 00120002
- The Accept_Test service abnormally ended while trying to write
to caller's parameter list.
- 00120003
- The Register_Test service abnormally ended because the caller's
parameter list was incorrect.
- 00120004
- The Register_Test service abnormally ended while trying to write
to caller's parameter list.
- 00120005
- The Unregister_Test service abnormally ended because the caller's
parameter list was incorrect.
- 00120006
- The Unregister_Test service abnormally ended while trying to write
to caller's parameter list.
- 001300xx
- An internal error occurred.
System Action: The system
action is unpredictable. -->
- 00140001
- The Register_For_Allocates service abnormally ended because the
caller specified a parameter list that contained too many or too few
parameters.
- 00140002
- The Register_For_Allocates service abnormally ended because the
system tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 00140003
- The Receive_Allocates service abnormally ended because the caller
specified a parameter list that contained too many or too few parameters.
- 00140004
- The Receive_Allocates service abnormally ended because the system
tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 00140005
- The Reject_Conversation service abnormally ended because the caller
specified a parameter list that contained too many or too few parameters.
- 00140006
- The Reject_Conversation service abnormally ended because the system
tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 00140007
- The Set_Allocate_Queue_Notification service abnormally ended because
the caller specified a parameter list that contained too many or too
few parameters.
- 00140008
- The Set_Allocate_Queue_Notification service abnormally ended because
the system tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 00140009
- The Get_Event service abnormally ended because the caller specified
a parameter list that contained too many or too few parameters.
- 0014000A
- The Get_Event service abnormally ended because the system tried
to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 0014000B
- The Query_Allocate_Queue service abnormally ended because the
caller specified a parameter list that contained too many or too few
parameters.
- 0014000C
- The Query_Allocate_Queue service abnormally ended because the
system tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 0014000D
- The Set_Allocate_Queue_Attributes service abnormally ended because
the caller specified a parameter list that contained too many or too
few parameters.
- 0014000E
- The Set_Allocate_Queue_Attributes service abnormally ended because
the system tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 0014000F
- The Set_Conversation_Accounting_ Information service abnormally
ended because the caller specified a parameter list that contained
too many or too few parameters.
- 00140010
- The Set_Conversation_Accounting_ Information service abnormally
ended because the system tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 00140011
- The Unregister_For_Allocates service abnormally ended because
the caller specified a parameter list that contained too many or too
few parameters.
- 00140012
- The Unregister_For_Allocates service abnormally ended because
the system tried to access one of the following:
- Input parameters to which the caller does not have read access
- Output parameters to which the caller does not have write access.
- 00140013 - 00140020
- An internal error occurred.
- 00150001 - 00150004
- During the activation of a logical unit (LU), APPC/MVS encountered
an error while attempting to perform resource manager restart processing.
System
Action: The system writes an SVC dump and continues processing.
APPC/MVS adds the LU to the configuration, but the LU can process
only conversations with a synchronization level of none or confirm.
- 00150005
- An internal error occurred.
System Action: The system
writes an SVC dump and continues processing. APPC/MVS accepts Allocate
requests for only conversations with a synchronization level of none
or confirm.
- 00150006
- During the activation of a logical unit (LU), APPC/MVS encountered
an error while attempting to perform resource manager restart processing.
System
Action: The system writes an SVC dump and continues processing.
APPC/MVS adds the LU to the configuration, but the LU can process
only conversations with a synchronization level of none or confirm.
- 00150008
- During the processing of a synchronization request, a partner
LU detected a syncpoint architecture protocol violation made by APPC/MVS
during the syncpoint transaction exchange.
System Action: The
system writes an SVC dump and continues processing. The syncpoint
request completes, but the state of the distributed resources is unknown;
a heuristic condition might exist. The syncpoint conversation is
deallocated by the partner.
- 00150009 - 0015000B
- An internal error occurred while the DISPLAY APPC command processor
was trying to extract data for display.
System Action: The
system writes an SVC dump and continues processing. The system ends
the DISPLAY command processing. Other APPC/MVS work continues.
- 0015000C
- An APPC LOGNAME mismatch has occurred between APPC and RRS.
System
Action: The system writes an SVC dump and continues processing.
APPC/MVS adds the LU to the configuration, but the LU can process
only conversations with a synchronization level of none or confirm.
System
programmer response: The logging value may have been changed in
the APPC PROC from either:
- LEGACY to RRSGNAME or
- RRSGNAME to LEGACY
If the LOGGING value has been changed, then check the
following:
- If the APPC logging value is incorrect, change it back to either
LEGACY or RRSGNAME (the opposite of what was currently specified),
and cancel and restart APPC.
- If the APPC logging value is correct and conversations with a
synchronization level of synchpoint are required, then it is necessary
to cancel both APPC and RRS using the following procedure:
- COLD START RRS's logstreams
- Restart both APPC and RRS
For more information, see Considerations when using the APPC LOGGING keyword in z/OS MVS Planning: APPC/MVS Management.
- 0015000D - 00150011
- During the activation of a logical unit (LU), APPC/MVS encountered
an error while attempting to perform resource manager restart processing.
System
Action: The system writes an SVC dump and continues processing.
APPC/MVS adds the LU to the configuration, but the LU can process
only conversations with a synchronization level of none or confirm.
- 00150012
- An internal error occurred.
System Action: The system
writes an SVC dump and continues processing. APPC/MVS accepts Allocate
requests for only conversations with a synchronization level of none
or confirm.
- 00150013 - 00150017
- APPC/MVS received an unexpected return code from an RRS callable
service during resynchronization processing for a unit of recovery,
associated with a protected conversation.
System Action: The
system writes an SVC dump and continues processing. The resynchronization
transaction processing ends, and the unit of recovery remains incomplete.
- 00150018
- An internal error occurred, causing the APPC/MVS resource manager
exits for an LU to become unset. Message ATB208I identifies the LU
whose resource manager exits have been unset.
System Action: The
system writes an SVC dump and continues processing. All active protected
conversations associated with the LU have ended abnormally. APPC/MVS
automatically re-registers the LU's exits.
- 0015001A - 0015001B
- An internal error occurred.
System Action: The system
writes an SVC dump and continues processing. The system does not purge
log-name affinities for partner LUs that established protected conversations
with an APPC/MVS LU.
- 0015001C
- During the activation of a logical unit (LU), APPC/MVS encountered
an error while attempting to perform resource manager restart processing.
System
Action: The system writes an SVC dump and continues processing.
APPC/MVS adds the LU to the configuration, but the LU can process
only conversations with a synchronization level of none or confirm.
- 0015001D - 00150028
- An internal error occurred.
System Action: The system
writes an SVC dump and continues processing. The system does not purge
log-name affinities for partner LUs that established protected conversations
with an APPC/MVS LU.
- 00150029 - 0015002A
- During the activation of a logical unit (LU), APPC/MVS encountered
an error while attempting to perform resource manager restart processing.
System
Action: The system writes an SVC dump and continues processing.
APPC/MVS adds the LU to the configuration, but the LU can process
only conversations with a synchronization level of none or confirm.
- 0015002B
- APPC/MVS reported an asynchronous abend during syncpoint processing.
System
Action: APPC/MVS continues to process the syncpoint. An asynchronous
abend may require APPC/MVS to perform re-synchronization to resolve
the unit of recovery.
- 0015002C
- An internal error occurred in APPC/MVS during syncpoint processing.
System
Action: The system continues processing. The system issues an
SVC dump.
- 0015002D
- An internal error occurred in APPC/MVS during syncpoint processing.
System
Action: The system continues processing. APPC/MVS may perform
re-synchronization to resolve the unit of recovery.
- 00150030
- RRS has been restarted with a different GNAME while APPC is active.
System
Action: The system writes an SVC dump and continues processing.
APPC/MVS adds the LU to the configuration, but the LU can process
only conversations with a synchronization level of none or confirm.
System
Programmer Response: Ensure that the GNAME specified on the RRS
PROC when RRS was restarted is correct. If the GNAME is specified
correctly, then cancel and restart APPC. For more information, see Considerations when using the APPC
keyword in z/OS MVS Planning: APPC/MVS Management.
- 00150031
- An internal error occurred.
System Action: The system
writes an SVC dump and continues processing. APPC/MVS accepts Allocate
requests for only conversations with a synchronization level of none
or confirm.
- 0016xxxx
- An internal error occurred.
System Action: Ensure that
the GNAME specified on the RRSPROC when RRS was restarted is correct.
If the GNAME is specified correctly then CANCEL and RESTART APPC.
- Allocate requests for conversations with a synchronization level
of syncpt
- Resynchronization processing to resolve incomplete units of recovery
and bring distributed resources to a consistent state.
- 0017xxxx
- An internal error occurred.
System Action: APPC continues
processing.