z/OS MVS System Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


042

z/OS MVS System Codes
SA38-0665-00

042

Explanation

A call for a base control program internal interface (BCPii) service was issued in an incorrect environment, or BCPii detected an unrecoverable error.

A hexadecimal reason code in register 15 explains the error:
Code
Explanation
00010000
For a call to the HWICMD service, the parameters passed by the caller are not in the primary address space.
00010001
For a call to the HWICMD service, the parameters passed by the caller are not accessible.
00010002
For a call to the HWICMD service, the number of the parameters passed by the caller is not correct.
00020000
For a call to the HWICONN service, the parameters passed by the caller are not in the primary address space.
00020001
For a call to the HWICONN service, the parameters passed by the caller are not accessible.
00020002
For a call to the HWICONN service, the number of the parameters passed by the caller is not correct.
00030000
For a call to the HWIDISC service, the parameters passed by the caller are not in the primary address space.
00030001
For a call to the HWIDISC service, the parameters passed by the caller are not accessible.
00030002
For a call to the HWIDISC service, the number of the parameters passed by the caller is not correct.
00040000
For a call to the HWIEVENT service, the parameters passed by the caller are not in the primary address space.
00040001
For a call to the HWIEVENT service, the parameters passed by the caller are not accessible.
00040002
For a call to the HWIEVENT service, the number of the parameters passed by the caller is not correct.
00050000
For a call to the HWILIST service, the parameters passed by the caller are not in the primary address space.
00050001
For a call to the HWILIST service, the parameters passed by the caller are not accessible.
00050002
For a call to the HWILIST service, the number of the parameters passed by the caller is not correct.
00060000
For a call to the HWIQUERY service, the parameters passed by the caller are not in the primary address space.
00060001
For a call to the HWIQUERY service, the parameters passed by the caller are not accessible.
00060002
For a call to the HWIQUERY service, the number of the parameters passed by the caller is not correct.
00070000
For a call to the HWISET service, the parameters passed by the caller are not in the primary address space.
00070001
For a call to the HWISET service, the parameters passed by the caller are not accessible.
00070002
For a call to the HWISET service, the number of the parameters passed by the caller is not correct.
xxxx0001
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0002
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0003
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0004
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0005
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0006
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0007
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0008
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0009
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx000A
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx000B
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx000C
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx000D
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx000E
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx000F
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0010
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0011
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0012
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0013
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0014
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0015
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0016
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0017
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0018
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0019
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx001A
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx001B
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx001C
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx001D
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx001E
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx001F
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0020
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0021
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0022
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0023
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0024
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0025
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0026
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0027
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0028
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0029
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx002A
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx002B
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx002C
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx002D
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx002E
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx002F
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0030
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0031
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0032
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0033
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0034
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0035
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0036
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
xxxx0037
xxxx is greater than or equal to 0100. An internal error occurred in BCPii.
Start of changexxxx0039End of change
Start of changexxxx is greater than or equal to 0100. An internal error occurred in BCPii.End of change

System action

Specific system actions for each reason code are as follows:
Code
System Action
00010000 through 00060002
The system rejects the service call.
xxxx0003,xxxx0005,xxxx0006,xxxx0007,xxxx0008,xxxx0009,xxxx000C,xxxx000D,xxxx000E,xxxx000F,xxxx0010,xxxx0012,
xxxx0013,xxxx0014,xxxx0016,xxxx0017,xxxx0018,xxxx0019,xxxx001A,xxxx001B,xxxx001C,xxxx001D,xxxx001E,xxxx001F,
xxxx0020,xxxx0021,xxxx0022,xxxx0023,xxxx0024,xxxx0025,xxxx0026,xxxx0027,xxxx0028,xxxx0029,xxxx002A,xxxx002B,
xxxx002C,xxxx002D,xxxx002E,xxxx002F,xxxx0030,xxxx0031,xxxx0032,xxxx0033,xxxx0034,
xxxx0035,xxxx0036,xxxx0037
BCPii continues processing, but the system does not perform the requested service. The system takes an SVC dump.
xxxx0001,xxxx0002,xxxx0004,xxxx000A,xxxx000B,xxxx0015,xxxx0017
The system abnormally ends the BCPii address space, and takes an SVC dump. No BCPii callable services are accepted by the system until the address space is manually restarted.

Operator response

If the abend recurs, notify the system programmer.

System programmer response

If the error recurs, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Programmer response

Respond as indicated for the specific reason code:
Code
Programmer Response
00010000 through 00060002
Check the calling program for a probable coding error; correct the program and run it again.
All other codes
Search problem reporting databases for a fix for the problem. If no fix exists, contact the IBM Support Center.

Source

HWIBCPII (BCPii) address space

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014