z/OS MVS Dump Output Messages
SA23-1378-00
IGW701I
The storage pointed to by
field
is inaccessible
IGW702I
The control block storage at address is inaccessible
IGW703I
Invalid control block detected at location address
IGW704I
SMSXDATA unable to get sufficient working storage
IGW705I
SMSXDATA must be invoked on an MVS/XA system
IGW707I
SMSXDATA terminated - PDSE support was not enabled on dumped system
IGW708I
ASID asid not found in dump source
IGW709I
JOBNAME jobname not found in dump source
IGW710I
SMSXDATA terminated - unable to parse requested options
IGW712I
SMSXDATA unable to print the module map
IGW716I
Requested ASID or JOBNAME contains no open PDSE dataset
IGW719I
Distributed FileManager Main Data Space
IGW722I
SMSXDATA verbexit processing
IGW724I
Invalid control block control block header
IGW725I
IPCS format services error attempting to format the control block
IGW726I
PDSE data for dsname pdse dsname
IGW729I
Zero dump pointer detected while accessing the control block
IGW730I
Global structures follow:
IGW731I
ASID asid jobstep TCB tcb address related structures follow:
IGW732I
Module map follows:
IGW734I
The control block control block length is greater than 4096
IGW735I
No data space in dump source to access the control block
IGW737I
ASID asid related structures follow:
IGW738I
Buffer Management Facility -- BMF
IGW739I
Index Management Facility -- IMF
IGW740I
Common Data Manager -- CDM
IGW741I
Common Lock Manager -- CLM
IGW742I
System Service Facilities -- SSF
IGW743I
BMF data space
IGW744I
Maximum chain threshold count count exceeded
IGW745I
The control block with storage key key is not in data management key 5
IGW746I
SMSXDATA terminated - unable to select ASID from dump source
IGW747I
Standard save area for csect csect name
IGW748I
Standard save area
IGW749I
Linkage stack general regs 0-15, access regs 0-15, PKM, SASN, EAX, PASN, PSW, TARG
IGW750I
Control regs 0-15 at time of ERROR (SDWACRER)
IGW751I
Access regs 0-15 at time of ERROR (SDWAARER)
IGW753I
SMSXDATA terminated - invalid component identifier
IGW754I
SDWA first recordable extension (SDWAARC1)
IGW757I
General regs 0-15 at time of ERROR (SDWAGRSV)
IGW758I
PSW at time of error/slip: psw (field)
IGW759I
Distributed FileManager
IGW760I
Request for storage beyond 7FFFFFFF while accessing the control block
IGW761I
General regs 0-15 at time of SLIP (PRDSLGPR)
IGW762I
Control regs 0-15 at time of SLIP (PRDSLCR)
IGW763I
Access regs 0-15 at time of SLIP (PRDSLAR)
IGW764I
SDWA from dump header record follows
IGW765I
No SDWA -- dump header record follows
IGW766I
Current/active member connection related structures
IGW767I
Access Method Adapter -- AMA
IGW768I
The control block data space storage at address is inaccessible