SYSOUT Selection Criteria Section

Triplet Information

This section is located on the record using the following triplet fields, which are located in the ‘Header/self-defining’ section:
Offset
SMF24OSP
Length
SMF24LSP
Number
SMF24NSP
Offsets Name Length Format Description
0 0 SMF24LN2 2 binary Length of SYSOUT section.
2 2 SMF24SFG 1 binary SYSOUT flags
Bit
Meaning when set
0
Held SYSOUT
1
Bursted SYSOUT
2
Held job
3
Incomplete data set
4
Multi-destination data set
5-7
Reserved.
3 3 SMF24SCL 1 EBCDIC SYSOUT class.
4 4 SMF24SND 8 EBCDIC Node name.
12 C SMF24SRN 8 EBCDIC Remote name.
20 14 SMF24FCB 4 EBCDIC Forms control buffer (FCB).
24 18 SMF24FOR 8 EBCDIC Forms overlay name.
32 20 SMF24FLS 4 EBCDIC Flash cartridge name.
36 24 SMF24PRM 8 EBCDIC Print data set (PR) mode.
44 2C SMF24UCS 4 EBCDIC Universal character set (UCS).
48 30 SMF24WID 8 EBCDIC Writer.
56 38 SMF24REC 4 binary Data set record count.
60 3A SMF24PRY 1 binary Output selection priority.