Automatic Restart Management Section

This section contains information related to a batch job or started task that registers as an element of automatic restart management. The element name, element type, and timestamps of the completion of various events are recorded. If the timestamp for an event is zero, then that particular event had not been completed by the time the record was generated.

Triplet Information

This section is located on the record using the following triplet fields, which are located in the ‘header/self-defining’ section:
Offset
SMF30RMO
Length
SMF30RML
Number
SMF30RMN
Offsets Name Length Format Description
0 0 SMF30RNM 16 EBCDIC Element name.
16 10 SMF30RTP 8 EBCDIC Element type.
24 18 SMF30RRG 16 EBCDIC Restart group for element in SMF30RNM.
40 28 SMF30RSN 8 EBCDIC The system name for the system on which the element was initially started; blank, for the initial start.
Note: The current system name is in the SMF30SYN field.
48 30 SMF30RGT 4 binary The time (local) when the element issued the IXCARM macro with the REGISTER parameter, in hundredths of a second.
52 34 SMF30RGD 4 binary The date when the element issued the REGISTER request, in the form 0cyydddF. See Standard SMF record header for a detailed description.
56 38 SMF30RWT 4 binary The time (local) when the element issued the IXCARM macro with the WAITPRED parameter, in hundredths of a second. This field will be zero if this function was not requested.
60 3C SMF30RWD 4 binary The date when the element issued IXCARM with the WAITPRED parameter, in the form 0cyydddF (where ‘F’ is the sign). This field will be zero if this function was not requested.
64 40 SMF30RYT 4 binary The time (local) when the element issued the IXCARM macro with the READY parameter, in hundredths of a second.
68 44 SMF30RYD 4 binary The date when this element issued the IXCARM macro with the READY parameter, in the format 0cyydddF (where ‘F’ is the sign).
72 48 SMF30RTT 4 binary The time (local) when the element was deregistered, in hundredths of a second. This field will be zero if this element is not yet deregistered or if it ended abnormally.
76 4C SMF30RTD 4 binary The date when this element was deregistered, in the format 0cyydddF. See Standard SMF record header for a detailed description. This field will be zero if this element is not yet deregistered or if it ended abnormally.