ASID Data Area Section

This section contains address space use during the interval.

Offsets Name Length Format Description
0 0 SMF70RMN 2 binary Ready minimum value over interval.
2 2 SMF70RMM 2 binary Ready maximum value over interval.
4 4 SMF70RTT 4 binary Ready total value over interval.
8 8 SMF70R00 4 binary Count of times ready value was zero.
12 C SMF70R01 4 binary Count of times ready value was 1.
16 10 SMF70R02 4 binary Count of times ready value was 2.
20 14 SMF70R03 4 binary Count of times ready value was 3.
24 18 SMF70R04 4 binary Count of times ready value was 4.
28 1C SMF70R05 4 binary Count of times ready value was 5.
32 20 SMF70R06 4 binary Count of times ready value was 6.
36 24 SMF70R07 4 binary Count of times ready value was 7.
40 28 SMF70R08 4 binary Count of times ready value was 8.
44 2C SMF70R09 4 binary Count of times ready value was 9.
48 30 SMF70R10 4 binary Count of times ready value was 10.
52 34 SMF70R11 4 binary Count of times ready value was 11.
56 38 SMF70R12 4 binary Count of times ready value was 12.
60 3C SMF70R13 4 binary Count of times ready value was 13.
64 40 SMF70R14 4 binary Count of times ready value was 14.
68 44 SMF70R15 4 binary Count of times ready value was 15 or more.
72 48 SMF70IMN 2 binary IN users minimum over interval.
74 4A SMF70IMM 2 binary IN users maximum over interval.
76 4C SMF70ITT 4 binary IN users total value over interval.
80 50 SMF70I00 4 binary Count of times IN users was zero.
80 54 SMF70I01 4 binary Count of times IN users was 1 or 2.
88 58 SMF70I02 4 binary Count of times IN users was 3 or 4.
92 5C SMF70I03 4 binary Count of times IN users was 5 or 6.
96 60 SMF70I04 4 binary Count of times IN users was 7 or 8.
100 64 SMF70I05 4 binary Count of times IN users was 9 or 10.
104 68 SMF70I06 4 binary Count of times IN users was 11 - 15.
108 6C SMF70I07 4 binary Count of times IN users was 16 - 20.
112 70 SMF70I08 4 binary Count of times IN users was 21 - 25.
116 74 SMF70I09 4 binary Count of times IN users was 26 - 30.
120 78 SMF70I10 4 binary Count of times IN users was 31 - 35.
124 7C SMF70I11 4 binary Count of times IN users was 36 or more.
128 80 SMF70OMN 2 binary Out users minimum over interval.
130 82 SMF70OMM 2 binary Out users maximum over interval.
132 84 SMF70OTT 4 binary Out users total value over interval.
136 88 SMF70O00 4 binary Count of times out users was zero.
140 8C SMF70O01 4 binary Count of times out users was 1 or 2.
144 90 SMF70O02 4 binary Count of times out users was 3 or 4.
148 94 SMF70O03 4 binary Count of times out users was 5 or 6.
152 98 SMF70O04 4 binary Count of times out users was 7 or 8.
156 9C SMF70O05 4 binary Count of times out users was 9 or 10.
160 A0 SMF70O06 4 binary Count of times out users was 11 - 15.
164 A4 SMF70O07 4 binary Count of times out users was 16 - 20.
168 A8 SMF70O08 4 binary Count of times out users was 21 - 25.
172 AC SMF70O09 4 binary Count of times out users was 26 - 30.
176 B0 SMF70O10 4 binary Count of times out users was 31 - 35.
180 B4 SMF70O11 4 binary Count of times out users was 36 or more.
184 B8 SMF70WMN 2 binary Wait user minimum over interval.
186 BA SMF70WMM 2 binary Wait users maximum over interval.
188 BC SMF70WTT 4 binary Wait users total value over interval.
192 C0 SMF70W00 4 binary Count of times wait users was zero.
196 C4 SMF70W01 4 binary Count of times wait users was 1 or 2.
200 C8 SMF70W02 4 binary Count of times wait users was 3 or 4.
204 CC SMF70W03 4 binary Count of times wait users was 5 or 6.
208 D0 SMF70W04 4 binary Count of times wait users was 7 or 8.
212 D4 SMF70W05 4 binary Count of times wait users was 9 or 10.
216 D8 SMF70W06 4 binary Count of times wait users was 11 - 15.
220 DC SMF70W07 4 binary Count of times wait users was 16 - 20.
224 E0 SMF70W08 4 binary Count of times wait users was 21 - 25.
228 E4 SMF70W09 4 binary Count of times wait users was 26 - 30.
232 E8 SMF70W10 4 binary Count of times wait users was 31 - 35.
236 EC SMF70W11 4 binary Count of times wait users was 36 or more.
240 F0 SMF70BMN 2 binary Batch users minimum over interval.
242 F2 SMF70BMM 2 binary Batch users maximum over interval.
244 F4 SMF70BTT 4 binary Batch users total value over interval.
248 F8 SMF70B00 4 binary Count of times batch users was zero.
252 FC SMF70B01 4 binary Count of times batch users was 1 or 2.
256 100 SMF70B02 4 binary Count of times batch users was 3 or 4.
260 104 SMF70B03 4 binary Count of times batch users was 5 or 6.
264 108 SMF70B04 4 binary Count of times batch users was 7 or 8.
268 10C SMF70B05 4 binary Count of times batch users was 9 or 10
272 110 SMF70B06 4 binary Count of times batch users was 11 - 15.
276 114 SMF70B07 4 binary Count of times batch users was 16 - 20.
280 118 SMF70B08 4 binary Count of times batch users was 21 - 25.
284 11C SMF70B09 4 binary Count of times batch users was 26 - 30.
288 120 SMF70B10 4 binary Count of times batch users was 31 - 35.
292 124 SMF70B11 4 binary Count of times batch users was 36 or more.
296 128 SMF70SMN 2 binary Started users minimum over interval.
298 12A SMF70SMM 2 binary Started users maximum over interval.
300 12C SMF70STT 4 binary Started users total value over interval.
304 130 SMF70S00 4 binary Count of times users was zero.
308 134 SMF70S01 4 binary Count of times users was 1 or 2.
312 138 SMF70S02 4 binary Count of times users was 3 or 4.
316 13C SMF70S03 4 binary Count of times users was 5 or 6.
320 140 SMF70S04 4 binary Count of times users was 7 or 8.
324 144 SMF70S05 4 binary Count of times users was 9 or 10.
328 148 SMF70S06 4 binary Count of times users was 11 - 15.
332 14C SMF70S07 4 binary Count of times users was 16 - 20.
336 150 SMF70S08 4 binary Count of times users was 21 - 25.
340 154 SMF70S09 4 binary Count of times users was 26 - 30.
344 158 SMF70S10 4 binary Count of times users was 31 - 35.
348 15C SMF70S11 4 binary Count of times users was 36 or more.
352 160 SMF70TMN 2 binary TSO/E users minimum over interval.
354 162 SMF70TMM 2 binary TSO/E users maximum over interval.
356 164 SMF70TTT 4 binary TSO/E users total value over interval.
360 168 SMF70T00 4 binary Count of times TSO/E users was zero.
364 16C SMF70T01 4 binary Count of times TSO/E users was 1 or 2.
368 170 SMF70T02 4 binary Count of times TSO/E users was 3 or 4.
372 174 SMF70T03 4 binary Count of times TSO/E users was 5 or 6.
376 178 SMF70T04 4 binary Count of times TSO/E users was 7 or 8.
380 17C SMF70T05 4 binary Count of times TSO/E users was 9 or 10.
384 180 SMF70T06 4 binary Count of times TSO/E users was 11 - 15.
388 184 SMF70T07 4 binary Count of times TSO/E users was 16 - 20.
392 188 SMF70T08 4 binary Count of times TSO/E users was 21 - 25.
396 18C SMF70T09 4 binary Count of times TSO/E users was 26 - 30.
400 190 SMF70T10 4 binary Count of times TSO/E users was 31 - 35.
404 194 SMF70T11 4 binary Count of times TSO/E users was 36 or more.
408 198 SMF70LMN 2 binary Logical ready users minimum over interval.
410 19A SMF70LMM 2 binary Logical ready users maximum over interval.
412 19C SMF70LTT 4 binary Logical ready users total value over interval.
416 1A0 SMF70L00 4 binary Count of times the number of logical ready users was zero.
420 1A4 SMF70L01 4 binary Count of times the number of logical ready users was 1 or 2.
424 1A8 SMF70L02 4 binary Count of times the number of logical ready users was 3 or 4.
428 1AC SMF70L03 4 binary Count of times the number of logical ready users was 5 or 6.
432 1B0 SMF70L04 4 binary Count of times the number of logical ready users was 7 or 8.
436 1B4 SMF70L05 4 binary Count of times the number of logical ready users was 9 or 10.
440 1B8 SMF70L06 4 binary Count of times the number of logical ready users was 11 - 15.
444 1BC SMF70L07 4 binary Count of times the number of logical ready users was 16 - 20.
448 1C0 SMF70L08 4 binary Count of times the number of logical ready users was 21 - 25.
452 1C4 SMF70L09 4 binary Count of times the number of logical ready users was 26 - 30.
456 1C8 SMF70L10 4 binary Count of times the number of logical ready users was 31 - 35.
460 1CC SMF70L11 4 binary Count of times the number of logical ready users was 36 or more.
464 1D0 SMF70AMN 2 binary Logical wait users minimum over interval.
466 1D2 SMF70AMM 2 binary Logical wait users maximum over interval.
468 1D4 SMF70ATT 4 binary Logical wait users total value over interval.
472 1D8 SMF70A00 4 binary Count of times the number of logical wait users was zero.
476 1DC SMF70A01 4 binary Count of times the number of logical wait users was 1 or 2.
480 1E0 SMF70A02 4 binary Count of times the number of logical wait users was 3 or 4.
484 1E4 SMF70A03 4 binary Count of times the number of logical wait users was 5 or 6.
488 1E8 SMF70A04 4 binary Count of times the number of logical wait users was 7 or 8.
492 1EC SMF70A05 4 binary Count of times the number of logical wait users was 9 or 10.
496 1F0 SMF70A06 4 binary Count of times the number of logical wait users was 11 - 15.
500 1F4 SMF70A07 4 binary Count of times the number of logical wait users was 16 - 20.
504 1F8 SMF70A08 4 binary Count of times the number of logical wait users was 21 - 25.
508 1FC SMF70A09 4 binary Count of times the number of logical wait users was 26 - 30.
512 200 SMF70A10 4 binary Count of times the number of logical wait users was 31 - 35.
516 204 SMF70A11 4 binary Count of times the number of logical wait users was 36 or more.
520 208 SMF70PMN 2 binary Minimum number of ASCH address spaces. An ASCH address space is scheduled by the APPC/MVS transaction scheduler.
522 20A SMF70PMM 2 binary Maximum number of ASCH address spaces.
524 20C SMF70PTT 4 binary Total number of ASCH address spaces.
528 210 SMF70P00 4 binary Number of times when 0 ASCH address spaces were found.
532 214 SMF70P01 4 binary Number of times when 1 - 2 ASCH address spaces were found.
536 218 SMF70P02 4 binary Number of times when 3 - 4 ASCH address spaces were found.
540 21C SMF70P03 4 binary Number of times when 5 - 6 ASCH address spaces were found.
544 220 SMF70P04 4 binary Number of times when 7 - 8 ASCH address spaces were found.
548 224 SMF70P05 4 binary Number of times when 9 - 10 ASCH address spaces were found.
552 228 SMF70P06 4 binary Number of times when 11 - 15 ASCH address spaces were found.
556 22A SMF70P07 4 binary Number of times when 16 - 20 ASCH address spaces were found.
560 230 SMF70P08 4 binary Number of times when 21 - 25 ASCH address spaces were found.
564 234 SMF70P09 4 binary Number of times when 26 - 30 ASCH address spaces were found.
568 238 SMF70P10 4 binary Number of times when 31 - 35 ASCH address spaces were found.
572 23A SMF70P11 4 binary Number of times when 36 or more ASCH address spaces were found.
576 240 SMF70XMN 2 binary Minimum number of OMVS address spaces.
578 242 SMF70XMM 2 binary Maximum number of OMVS address spaces.
580 244 SMF70XTT 4 binary Total number of OMVS address spaces.
584 248 SMF70X00 4 binary Number of times when zero OMVS address spaces were found.
588 24C SMF70X01 4 binary Number of times when 1 - 2 OMVS address spaces were found.
592 250 SMF70X02 4 binary Number of times when 3 - 4 OMVS address spaces were found.
596 254 SMF70X03 4 binary Number of times when 5 - 6 OMVS address spaces were found.
600 258 SMF70X04 4 binary Number of times when 7 - 8 OMVS address spaces were found.
604 25C SMF70X05 4 binary Number of times when 9 - 10 OMVS address spaces were found.
608 260 SMF70X06 4 binary Number of times when 11 - 15 OMVS address spaces were found.
612 264 SMF70X07 4 binary Number of times when 16 - 20 OMVS address spaces were found.
616 268 SMF70X08 4 binary Number of times when 21 - 25 OMVS address spaces were found.
620 26C SMF70X09 4 binary Number of times when 26 - 30 OMVS address spaces were found.
624 270 SMF70X10 4 binary Number of times when 31 - 35 OMVS address spaces were found.
628 274 SMF70X11 4 binary Number of times when 36 or more OMVS address spaces were found.
Fields SMF70Q00 to SMF70Q12 count the In Ready users based on the number N of Start of changelogicalEnd of change processors being online when the sample was taken. With HiperDispatch mode active and an SMF record level SMF70SRL ≥ X'55'(85), N is the number of Start of changelogicalEnd of change processors being online and not parked when the sample was taken.
632 278 SMF70Q00 4 binary Count of times In Ready users was less or equal N.
636 27C SMF70Q01 4 binary Count of times In Ready users was N+1.
640 280 SMF70Q02 4 binary Count of times In Ready users was N+2.
644 284 SMF70Q03 4 binary Count of times In Ready users was N+3.
648 288 SMF70Q04 4 binary Count of times In Ready users was N+4 or N+5.
652 28C SMF70Q05 4 binary Count of times In Ready users was N+6 to N+10.
656 290 SMF70Q06 4 binary Count of times In Ready users was N+11 to N+15.
660 294 SMF70Q07 4 binary Count of times In Ready users was N+16 to N+20.
664 298 SMF70Q08 4 binary Count of times In Ready users was N+21 to N+30.
668 29C SMF70Q09 4 binary Count of times In Ready users was N+31 to N+40.
672 2A0 SMF70Q10 4 binary Count of times In Ready users was N+41 to N+60.
676 2A4 SMF70Q11 4 binary Count of times In Ready users was N+61 or N+80.
680 2A8 SMF70Q12 4 binary Count of times In Ready users was greater than N+80.
684 2AC SMF70SRM 4 binary Number of samples taken by SRM
688 2B0 SMF70CMN 4 binary Minimum number of work units for general purpose processors over interval.
692 2B4 SMF70CMM 4 binary Maximum number of work units for general purpose processors over interval.
696 2B8 SMF70CTT 4 binary Total number of work units for general purpose processors over interval.
700 2BC SMF70DMN 4 binary Minimum number of work units for zAAPs over interval.
704 2C0 SMF70DMM 4 binary Maximum number of work units for zAAPs over interval.
708 2C4 SMF70DTT 4 binary Total number of work units for zAAPs over interval.
712 2C8 SMF70EMN 4 binary Minimum number of work units for zIIPs over interval.
716 2CC SMF70EMM 4 binary Maximum number of work units for zIIPs over interval.
720 2D0 SMF70ETT 4 binary Total number of work units for zIIPs over interval.
Fields SMF70U00 to SMF7U015 count the number of work units based on the number N of Start of changelogicalEnd of change processors being online when the sample was taken. With HiperDispatch mode active, N is the number of Start of changelogicalEnd of change processors being online and not parked when the sample was taken.
724 2D4 SMF70U00 4 binary Count of times the number of work units was less or equal N.
728 2D8 SMF70U01 4 binary Count of times the number of work units was N+1.
732 2DC SMF70U02 4 binary Count of times the number of work units was N+2.
736 2E0 SMF70U03 4 binary Count of times the number of work units was N+3.
740 2E4 SMF70U04 4 binary Count of times the number of work units was N+4 or N+5.
744 2E8 SMF70U05 4 binary Count of times the number of work units was between N+6 and N+10.
748 2EC SMF70U06 4 binary Count of times the number of work units was between N+11 and N+15.
752 2F0 SMF70U07 4 binary Count of times the number of work units was between N+16 and N+20.
756 2F4 SMF70U08 4 binary Count of times the number of work units was between N+21 and N+30.
760 2F8 SMF70U09 4 binary Count of times the number of work units was between N+31 and N+40.
764 2FC SMF70U10 4 binary Count of times the number of work units was between N+41 and N+60.
768 300 SMF70U11 4 binary Count of times the number of work units was between N+61 and N+80.
772 304 SMF70U12 4 binary Count of times the number of work units was between N+81 and N+100.
776 308 SMF70U13 4 binary Count of times the number of work units was between N+101 and N+120.
780 30C SMF70U14 4 binary Count of times the number of work units was between N+121 and N+150.
784 310 SMF70U15 4 binary Count of times the number of work units was greater N+150.