LOGLMT=nnnnnn
Example: LOGLMT=004852
In this example, when 4,852 WTLs have been issued to a log data set, the data set is scheduled for sysout processing on the output class specified by the LOGCLS parameter. Log processing then allocates and opens a new log data set.
If the specified value is not valid or an I/O error occurs while the IEASYSxx member is being read, master scheduler initialization prompts the operator for a replacement LOGLMT value. If prompting is forbidden (the OPI operand was specified), the default value of 500 is assigned.
For the other log parameter, see LOGCLS.
Value Range: 000000-999999
Default Value: 500
Associated Parmlib Member: None