The
two alphanumeric characters, represented by aa (or bb, and so on),
specify one or more COMMNDxx members of parmlib. The installation
can specify multiple members. Each member can contain automatic operator
commands that the installation wants processed during master scheduler
initialization. Examples of such commands are those that start GTF.
Job entry subsystem commands are not accepted because automatic commands
are processed before the job entry subsystem (JES2 or JES3) is started.
If
the CMD parameter is not specified, the COMMND00 member is used if
it exists. If COMMND00 does not exist or cannot be read, initialization
continues without any internally issued commands.
Value
Range: Any two alphanumeric characters.
Default
Value: CMD=00
Associated Parmlib Member:
COMMNDxx