z/OS MVS Programming: Callable Services for High-Level Languages
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Authorization

z/OS MVS Programming: Callable Services for High-Level Languages
SA23-1377-02

The client application must have access to consult the local CPC. This is granted by allowing the application at least read access to the SAF-protected FACILITY class resource HWI.APPLNAME.HWISERV.

The client application must have at least control access to the following SAF-protected FACILITY class resource profiles:
  • HWI.TARGET.netid.nau for a ConnectToken that represents a CPC connection or an image group connection.
  • HWI.TARGET.netid.nau.imagename for a ConnectToken that represents an image connection.
  • HWI.TARGET.netid.nau.imagename for all individual images within the image group for a ConnectToken that represents a user-defined image group.
Note: BCPii requires the FACILITY class to be RACLIST-specified.

Go to the previous page Go to the next page