INDMVCLK and INDMVCL64 - Move character long in user key

INDMVCLK input register values must be 31-bit addresses. INDMVCLK64 input register values must be 64-bit addresses. Before issuing the macro, the user must load the registers as follows:
Register
Use
0
Used as a work register by the system
2
Real location into which the characters are to be moved
3
Length of the area into which the characters are to be moved
4
Real location of the area from which the characters are to be moved
5
Length of the area from which the characters are to be moved
6
Bits 24-27 contain the PSW key in which the MVCL function is to be performed
14
Used as a work register by the system
15
Used as a work register by the system
1,7-13
Unused
The user invokes the 31-bit MVCL in user key function by coding the following macro:
DATOFF INDMVCLK