X'00' |
Successful Execution of Library Function |
X'0000' |
For an asynchronous request to an
ATLDS, the mount order has been successfully scheduled for later execution
by the library. For a synchronous request to an ATLDS, the mount completed
without error. For a request to an MTL, the WTO/WTOR message has been
issued, if requested. |
Yes |
Yes |
N/A |
X'04' |
Successful Execution of Non-Library
Function |
X'0000' |
The drive does not reside in a library.
If requested, the WTO/WTOR message has been issued. |
No |
No |
N/A |
X'08' |
Execution of Library Function Complete
with Warning |
X'0101' |
The requested ATLDS mount is complete,
but the library vision system has failed, preventing verification
of the external volume serial number. This code is set only after
a synchronous request. |
Yes |
No |
CBR4001I |
|
|
X'0102' |
The requested ATLDS mount is complete,
but the external label on the cartridge is either missing or unreadable.
This code is set only after a synchronous request. |
Yes |
No |
CBR4002I |
|
|
X'010C' |
The ATLDS mounted the scratch volume
as requested, but during the attempt to load the volume into the drive,
it was determined that the cartridge is damaged. The scratch mount
can be retried. This code is set only after a synchronous request. |
Yes |
No |
CBR4012I |
X'0C' |
Invalid Parameter List |
X'0121' |
A UCBPTR value has not been supplied,
or the UCB address is invalid. |
N/A |
N/A |
CBR4033I |
|
|
X'0122' |
A VOLSER value has not been supplied,
or the volume serial number is all blanks. |
N/A |
N/A |
CBR4034I |
|
|
X'0123' |
A TOKEN address has not been supplied. |
N/A |
N/A |
CBR4035I |
|
|
X'0125' |
Either a WTOCONS value or a WTOCART
value has been supplied, but a WTOPTR value has not. |
N/A |
N/A |
CBR4037I |
|
|
X'0127' |
More than one synchronization option
(ECBPTR, EXITPTR, or WAIT) has been supplied. |
N/A |
N/A |
CBR4039I |
|
|
X'012C' |
Either a WTOCONS value or a WTOCART
value has been supplied, but the WTO parameter list is in the normal
(WPL) format, rather than the extended (WPX) format. |
N/A |
N/A |
CBR4044I |
|
|
X'0130' |
A DEVTYPE address for tape device
selection information has not been supplied. |
N/A |
N/A |
CBR4048I |
|
|
X'0131' |
The tape device selection information
media type is invalid. |
N/A |
N/A |
CBR4049I |
|
|
X'0132' |
The volume serial number supplied
is invalid. The volume serial number must consist of all alphanumeric
characters, national characters ( @, $, # ) or special characters
( , . / ' ( ) * & + — = ) with no imbedded blanks. |
No |
Yes |
CBR4050I |
X'10' |
Environmental Error |
None |
CBRXLACS FUNC(MOUNT) does not use
the environmental error return code. |
|
|
|
X'14' |
Execution Failed with Permanent Error |
X'0161' |
The library where the mount is to
be performed is offline. |
Yes |
No |
CBR4097I |
|
|
X'0162' |
The library where the mount is to
be performed is not operational. |
Yes |
No |
CBR4098I |
|
|
X'0163' |
A permanent I/O error was detected
by the Asynchronous Operations Manager; a library sense record is
not available. |
Yes |
No |
CBR4099I |
|
|
X'0164' |
An equipment check occurred in the
library attachment facility or the library manager. |
Yes |
No |
CBR4100I |
|
|
X'0165' |
The microcode levels in the control
unit and the library manager cannot coexist. |
Yes |
No |
CBR4101I |
|
|
X'0166' |
One of the following situations has
occurred: - The library responded to the mount order with a unit check. The
code in the sense record is an unexpected and inappropriate response
to the order; for example, a code appropriate to a scratch mount was
received in response to a specific mount.
- The attention message that signaled the completion of the mount
order contained an undefined mount completion code.
|
Yes |
No |
CBR4102I |
|
|
X'0167' |
The requested volume is currently
in use. One of the following conditions is present in the library:
- The volume is already mounted on some drive in the library.
- A mount of the volume is pending on some drive in the library.
|
Yes |
No |
CBR4103I |
|
|
X'0168' |
The requested volume is not in the
library. |
Yes |
Yes |
CBR4104I |
|
|
X'0169' |
There are no volumes in the library
that are assigned to the required scratch category or categories. |
Yes |
No |
CBR4105I |
|
|
X'016A' |
An invalid sequence of orders has
been sent to the library. One of the following conditions is present
in the library: - A volume is already mounted on the drive, and no demount request
is pending.
- A mount request is already queued for the drive.
|
Yes |
No |
CBR4106I |
|
|
X'016B' |
The requested volume is not in the
location assigned to it in the library manager inventory. |
Yes |
No |
CBR4107I |
|
|
X'0170' |
An incompatible function has been
requested of the library. The control unit supports library commands,
but the library attachment interface is not installed. |
Yes |
No |
CBR4112I |
|
|
X'0171' |
No libraries are defined in the current
configuration. |
Yes |
No |
CBR4113I |
|
|
X'0172' |
The library configuration has not
yet been set. |
Yes |
No |
CBR4114I |
|
|
X'0174' |
The library manager is offline. |
Yes |
No |
CBR4116I |
|
|
X'0175' |
The requested volume is inaccessible
in the library. |
Yes |
No |
CBR4117I |
|
|
X'0176' |
The drive on which the volume was
to have been mounted is no longer available. It was made unavailable
by the library manager after repeated device errors or by the library
operator. This code is set only after a synchronous request. |
Yes |
No |
CBR4118I |
|
|
X'0177' |
The request cannot be completed because
the library name associated with the tape drive cannot be determined. |
No |
Yes |
CBR4119I |
|
|
X'0178' |
The mount request was sent to the
library, but no response has been received from the library. Either
the request completed and the completion message was lost, or the
request was lost in the library. This code is set only after a synchronous
request. |
Yes |
No |
CBR4120I |
|
|
X'0179' |
The requested cartridge is damaged
in such a way that it cannot be loaded into a tape drive. This code
is set only after a synchronous request. |
Yes |
No |
CBR4122I |
|
|
X'017A' |
The library mounted the volume as
requested, however the attempt to load the volume into the drive failed.
This code is set only after a synchronous request. |
Yes |
No |
CBR4011I |
|
|
X'017B' |
An incompatible function has been
requested of the library. The media type of the volume to be mounted
cannot coexist with the drive. The media type in the library manager
database is inconsistent with the media type of the volume in the
tape configuration database. |
Yes |
No |
CBR4123I |
|
|
X'017C' |
The drive on which volume was to
have been mounted was left in stand-alone mode at the library. |
Yes |
No |
CBR4124I |
|
|
X'017D' |
A valid copy of the requested volume
is inaccessible in the library. |
Yes |
No |
CBR4125I |
|
|
X'017E' |
The drive on which the scratch volume
was to have been mounted is in read-only mode. |
Yes |
No |
CBR4126I |
|
|
X'0191' |
The library does not have enough
physical drives available. |
Yes |
No |
CBR4127I |
|
|
X'0192' |
The library is out of empty stacked
volumes. |
Yes |
No |
CBR428I |
|
|
X'0193' |
The previous (clone) volser of the
multivolume dataset does not reside in the library. |
Yes |
No |
CBR4170I |
|
|
X'0194' |
The library encountered a failure
when attempting to mount the logical volume. This code is only set
after a synchronous request. |
Yes |
No |
CBR4171I |
|
|
X'0195' |
The mount request was cancelled at
the library and could not be completed prior to the library being
varied offline by an operator at the library manager. This code is
only set after a synchronous request. |
Yes |
No |
CBR4172I |
|
|
X'0196' |
The specified I/O VTS in the PtP
VTS subsystem is not available. |
Yes |
No |
CBR4173I |
|
|
X'0197' |
The library could not obtain volume ownership information. |
Yes |
No |
CBR4174I |
|
|
X'0198' |
Selective Device Access Control Group denied request. |
Yes |
No |
CBR4175I |
|
|
X'0199' |
Selective Device Access Control Group is not valid. |
Yes |
No |
CBR4176I |
|
|
X'019A' |
WORM volume metadata is inconsistent between the library and
the volume. This code is set only after a synchronous request. |
Yes |
No |
CBR4177I |
|
|
X'019B' |
Library is not WORM enabled. |
Yes |
No |
CBR4178I |
X'18' |
Execution failed due to system service
failure |
X'0181' |
LACS was unable to establish an ESTAE
exit routine. The ESTAE return code is stored in the LAPL in field
LAPSRET. |
N/A |
N/A |
CBR4129I |
|
|
X'0183' |
LACS was unable to write the caller's
message to the requested destination. The WTO return code is stored
in the LAPL in field LAPSRET. This reason code is associated only
with a non-ATLDS mount request; failure to write to the system log
does not cause failure of an ATLDS mount request. |
No |
Yes |
CBR4131I |
|
|
X'0184' |
LACS was unable to send the mount
order to the library using the LIBSERV service. The LIBSERV return
code and reason code are stored in the LAPL in fields LAPSRET and
LAPSREAS, respectively. |
Yes |
No |
CBR4132I |
X'1C' |
Abnormal Termination in LACS |
X'01A1' |
An abnormal termination occurred
during LACS execution. The system completion code is stored in the
LAPL in field LAPSRET. The ABEND reason code, if any, is stored in
the LAPL in field LAPSREAS. |
N/A |
N/A |
CBR4161I |