z/OS DFSMSdfp Diagnosis
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


IEC006I

z/OS DFSMSdfp Diagnosis
SC23-6863-00

UNABLE TO ACTIVATE A VIO DATA SET DURING RESTART PROCESSING

Explanation

Auxiliary storage management (ASM) was unable to reset its control blocks for a VIO data set to the data set's status at the time it was journaled. This message should be followed by message IEF086I.

System action

Terminate restart processing.

Programmer response

Rerun job. Also refer to message IEF086I.

Problem determination

ASM Module that Detects the Error: ILRGOS.

VIO Module that Issues Message: Module IDAVBPJ2 examines the return code in register 15 that is returned by ASM, and, if the return code is greater than 8, IDAVBPJ2 issues the message.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014