- TYPE=TAPE
- Specifies a request related to the TCDB.
- FUNC=EJECT
- Specifies a request to eject or query the eject status of a
tape volume from a tape library.
- VOLUME=volume-serial-number
- Specifies the name of a character variable (six-byte length)
that contains the volume serial number of the volume to be ejected.
The volume serial number must be left justified in the field and padded
on the right with blanks.
- EJECTOPT=KEEP
- Specifies that the TCDB record for the tape volume being ejected
should not be deleted after the eject completes
successfully.
- EJECTOPT=PURGE
- Specifies that the TCDB record for the tape volume being ejected
should be deleted after the eject completes successfully.
If the
EJECTOPT parameter is specified on the macro invocation, the cartridge
eject installation exit may override it.
If the EJECTOPT parameter
value is not specified on the macro invocation, the eject default
is used. (This default is established when the library is defined
by the storage administrator using the ISMF library define panel.)
However, the cartridge eject installation exit (CBRUXEJC) may ultimately
override the value.
- EJECTOPT=QUERY
- Specifies a request to query the OAM internal work queues to
determine if an eject request is pending. CBRXLCS FUNC=QVR should
be invoked first to determine if an eject request is pending at the
library or if the eject request has completed. If the status of the
eject request from the QVR function cannot be determined, you can
use this option to determine if the eject request resides on an OAM
internal queue but might not have been sent to the library yet.
- BULKEJCT=YES
- Specifies that the ejected cartridge be placed in the high-capacity
output station of an ATLDS. If this parameter is not specified or
the high-capacity output station is not configured, the cartridge
is placed in the convenience output station. If a convenience station
is not installed in a 3494, the cartridge is placed in the single
cell output area.
- BULKEJCT=NO
- Specifies that the cartridge be placed in the convenience output
station of an ATLDS. This is the default.
Note: For a manual
tape library, BULKEJCT is ignored.
- EXITINFO=installation-exit-information
- Specifies the name of a character variable (16-byte length)
that contains a customer specified free-form value that is passed
to the cartridge eject installation exit (CBRUXEJC).
- USERID=userid
- Specifies the name of a character variable (8-byte length) that
contains a TSO user ID. The field must be left-justified and padded
on the right with blanks.
After the eject request is successfully
scheduled (a zero return and reason code from the CBRXLCS macro invocation),
eject completion or failure messages are sent to this user ID through
the system services SEND interface.
|