z/OS Security Server RACF System Programmer's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Failures using sysplex data sharing

z/OS Security Server RACF System Programmer's Guide
SA23-2287-00

When a problem with the coupling facility prevents RACF® from entering data sharing mode, RACF provides several alternatives for recovery. See z/OS Security Server RACF Diagnosis Guide for information about sysplex recovery.

Note: Do not issue a SETXCF command to force the rebuild of a structure into a coupling facility that is not available to the system. Do not issue the RVARY DATASHARE command when there is no coupling facility available. These actions cause the system to enter read-only mode. To exit read-only mode after an inappropriate SETXCF command, issue the RVARY DATASHARE command and RACF will use the original coupling facility. To exit read-only mode after an inappropriate RVARY DATASHARE command, or in other situations when no coupling facility is available, issue the RVARY NODATASHARE command.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014