z/OS DFSORT Messages, Codes and Diagnosis Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ICE202I

z/OS DFSORT Messages, Codes and Diagnosis Guide
SC23-6879-00

ICE202I
SYSUT2 LRECL OF x IS DIFFERENT FROM SYSUT1 LRECL OF y - RC=n

Explanation

The ICEGENER application was successfully processed, but the SYSUT2 LRECL (x) and SYSUT1 LRECL (y) were not equal. ICEGENER set a return code of 0 or 4 as indicated by n. ICEGENER only set a return code of 4 if:
  • Installation option GNPAD=RC4 was specified and x was larger than y (LRECL padding), or
  • Installation option GNTRUNC=RC4 was specified and x was smaller than y (LRECL truncation).

System action

Processing continues and ICEGENER passes back a return code of n unless it sets a higher return code for some other reason.

Programmer response

If appropriate, change the LRECL of SYSUT1 or SYSUT2 so that the LRECLs are equal.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014