Figure 1 is a sample of output from
trace identifier 46. Trace identifier 46 traces the ENF70 event that
is being received.
Figure 1. Sample Output from Trace Identifier 4617.11.56.01740 ID= 45 ENF70 JOB00024 004AE7B8 IBMUSERA Member=IBM1 Type=RECEIVE Select ---------
JESPLEX Id=12561142 0112159F Job Key=C9AF89E2 MAXCC=00000000 Selected by phase processing Phase=Input
JOBCLASS=A SRVCLASS=........
0 C5D5C6F7 F0400100 00000090 00780100 0000C9C2 D4F14040 40401256 11420112 *ENF70 ............IBM1 ......*
20 159FC9C2 D4E4E2C5 D9C1D1D6 C2F0F0F0 F2F4D1D6 C2F0F0F0 F2F4D7D6 D2404040 *..IBMUSERAJOB00024JOB00024POK *
40 4040C140 40404040 40400000 00000000 00000000 0112159F 005E79B3 00000000 * A ...............;......*
60 80000000 0000C9AF 89E20000 00180000 00050000 00000000 C5D5C6F7 F0E70018 *......I.iS..............ENF70X..*
80 00000000 00000000 00000400 00000000 *................ *
The trace output contains the following:
- The Job number, Job key, Job class and Service class of the Job
whose phase change resulted in ENF70 being signalled.
- The JESPLEX ID and Member that is issuing the ENF70 event.
Note: - ENF58 events that are signalled by other members in the MAS are
traced. ENF58 events that are signalled by the same member and ENF58
events that are signalled by members in another MAS are not traced.
- Traces might not be available for secondary subsystems or if SYSLOG
is not active.