z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZB3850E

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZB3850E
Status change for unknown interface interface

Explanation

NCPROUTE received a status change request PDU from the NCP client for an interface that was unknown. Either NCPROUTE did not completely read in the NCP client's Routing Information Table (RIT), or the RIT was not built correctly during NCP generation. Another possible cause is that the NCP client dynamically added the interface to its tables. Dynamically-added interfaces are not currently supported by NCPROUTE. The Status PDU is discarded.

System action

NCPROUTE continues.

Operator response

None.

System programmer response

Check the interface configuration messages created in the console log at install time to verify that the interfaces defined in the NCP client's generation match the interfaces processed by NCPROUTE. If a mismatch is found, verify that the RIT is built correctly. If the problem cannot be corrected, contact IBM® software support services.

Module

NRPDUS

Procedure name

recv_status

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014