Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
EZY1220E: mm/dd/yy hh:mm:ss READ FAILURE ON CONFIGURATION FILE PHASE=phase EIBRESP2=response z/OS Communications Server: IP CICS Sockets Guide SC27-3649-00 |
|
ExplanationEZACIC21 was unable to read the IP CICS® Sockets configuration file, EZACONFG. mm/dd/yy is the date (month/day/year) of the message. hh:mm:ss is the time (hours:minutes:seconds) of the message. phase is the IP CICS Sockets initialization phase. response is the response from CICS when reading the IP CICS Sockets configuration file. System actionIf the ABEND code is AEXY, then the listener ends normally. Otherwise, the listener ends with an ABEND code of EZAL. Operator responseNotify the CICS system programmer. System programmer responseUse the EIBRESP2 value to determine the problem and correct the file. See http://www-01.ibm.com/software/htp/cics/library/ for information about EIBRESP2 values. If the EIBRESP2 value is zero, then the EZACONFG file has been defined as remote. If this is the configuration file you want, then verify that no CICS Sockets programs can run directly in the file owning region. This can cause the file to become disabled. Ensure that EZACIC20 is not in the file owning region PLT, and that the EZAC and EZAO transactions are unable to run directly in the file owning region. Attempts to open the file will fail if the file is defined with a value of YES specified in the ADD, DELETE, or UPDATE parameters in the CICS file definition in more than one CICS region. ModuleEZACIC21 DestinationINITIALIZATION |
Copyright IBM Corporation 1990, 2014
|