z/OS Communications Server: IP CICS Sockets Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZY1220E: mm/dd/yy hh:mm:ss READ FAILURE ON CONFIGURATION FILE PHASE=phase EIBRESP2=response

z/OS Communications Server: IP CICS Sockets Guide
SC27-3649-00

Explanation

EZACIC21 was unable to read the IP CICS® Sockets configuration file, EZACONFG.

mm/dd/yy is the date (month/day/year) of the message.

hh:mm:ss is the time (hours:minutes:seconds) of the message.

phase is the IP CICS Sockets initialization phase.

response is the response from CICS when reading the IP CICS Sockets configuration file.

System action

If the ABEND code is AEXY, then the listener ends normally. Otherwise, the listener ends with an ABEND code of EZAL.

Operator response

Notify the CICS system programmer.

System programmer response

Use the EIBRESP2 value to determine the problem and correct the file. See http://www-01.ibm.com/software/htp/cics/library/ for information about EIBRESP2 values. If the EIBRESP2 value is zero, then the EZACONFG file has been defined as remote. If this is the configuration file you want, then verify that no CICS Sockets programs can run directly in the file owning region. This can cause the file to become disabled. Ensure that EZACIC20 is not in the file owning region PLT, and that the EZAC and EZAO transactions are unable to run directly in the file owning region. Attempts to open the file will fail if the file is defined with a value of YES specified in the ADD, DELETE, or UPDATE parameters in the CICS file definition in more than one CICS region.

Module

EZACIC21

Destination

INITIALIZATION

Go to the previous page Go to the next page