z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ0148I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ0148I
PORT STATEMENT KEYWORD WHENLISTEN ON LINE lineno IS NOT VALID FOR UDP PROTOCOL

Explanation

The WHENLISTEN keyword was specified on a PORT statement UNRSV entry that specifies the UDP protocol. The WHENLISTEN keyword is a valid access control only for the TCP protocol; it is not valid for the UDP protocol. The WHENBIND keyword is the only valid access control (and is the default value) for the UDP protocol.

In the message text:
lineno
The line number in the profile data set that contains the error.

System action

If processing an initial profile or a VARY TCPIP,,OBEYFILE command, the entire PORT statement is ignored. Profile processing continues.

This message is also displayed as part of VARY TCPIP,,SYNTAXCHECK processing when the VARY TCPIP,,SYNTAXCHECK command detects this error in a profile data set. No changes are applied to the active configuration by VARY TCPIP,,SYNTAXCHECK processing.

Operator response

Contact the system programmer.

System programmer response

  1. Correct the statement with one of these changes:
    • Remove the incorrect UNRSV entry from the PORT statement.
    • Change the access control to WHENBIND.
    • Change the protocol to TCP.
  2. If this message was displayed as a result of a VARY TCPIP,,SYNTAXCHECK command, issue the VARY TCPIP,,SYNTAXCHECK command again to verify that you have removed all syntax errors from the profile. Otherwise, issue a VARY TCPIP,,OBEYFILE command with a profile that contains the entire PORT statement.

See the PORT statement in z/OS Communications Server: IP Configuration Reference for more information.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP: Configuration & Initialization

Module

ezacfppt.c

Routing code

10

Descriptor code

12

Automation

This message is directed to the console. You can use automation to detect and respond to TCP/IP profile errors reported during initial profile and VARY TCPIP,,OBEYFILE processing.

This message can also be displayed during VARY TCPIP,,SYNTAXCHECK processing. Because the VARY TCPIP,,SYNTAXCHECK command does not affect the active configuration, you might want to adjust your automation to ignore the configuration messages that are displayed after EZZ0061I and before EZZ0065I.

Example

EZZ0148I PORT STATEMENT  KEYWORD WHENLISTEN ON LINE 8  IS NOT VALID FOR UDP  PROTOCOL  

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014