Figure 1. SYSMOD comparison HOLDDATA report:
standard formatPAGE nnnn - NOW SET TO zzzzzz ZONE nnnnnnnn DATE mm/dd/yy TIME hh:mm:ss SMP/E 36.nn SMPHRPT OUTPUT
SYSMOD COMPARISON HOLDDATA REPORT FOR ztype ZONE zone1 AND ztype ZONE zone2
IN THE GLOBAL ZONE IN CSI csidataset
TYPE REASON ID FMID SYSMOD ++HOLD DATA
------ --------- ------- ------- --------------------------------------------------------------------------------
aaaaaa bbbbbbb ccccccc ddddddd eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
ddddddd eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
ccccccc ddddddd eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
bbbbbbb ccccccc ddddddd eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
ccccccc ddddddd eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
These are the fields in the report:
- ztype
- is the zone type being reported on. It may be either TARGET or
DLIB.
- zone1
- is the name of the input zone.
- zone2
- is the name of the comparison zone.
- csidataset
- the global zone CSI data set name for the COMPAREDTO zone. This
data set name is included in the report only if it differs from the
global zone CSI data set name for the input zone.
- TYPE
- is the type of HOLD for the following reason ID.
- SYSTEM
- indicates a system hold
- USER
- indicates a user hold
- REASONID
- reason ID that identifies why the SYSMOD should be held
- FMID
- is the FMID of the held SYSMOD being reported (shown in the SYSMOD
field)
- SYSMOD
- is the ID identified in the ++HOLD statement as the held SYSMOD
- ++HOLD DATA
- this is one of the following selections:
- the ++HOLD MCS that was received for the HOLD reason ID. This
data can span several lines and is provided for each reason ID, or
- an indication that the ++MCS has been suppressed
for the reason IDs specified in the Suppress HOLDDATA (SUPPHOLD) subentry
of the OPTIONS entry.