IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


XCF_CF_ALLOCATION_PERMITTED

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Description:
Check that, for each coupling facility in the CFRM active policy, structure allocation is permitted.
Reason for check:
If coupling facilities are not eligible for structure allocation, they should not remain in maintenance mode or any other state for any extended period of time. If the check shows a warning during maintenance or upgrade windows, the warning serves as a reminder to turn off maintenance mode when the service action is completed.
Parameters accepted:
None.
z/OS® releases the check applies to:
z/OS V1R10 and later.
User override of IBM® values:
The following shows the default keywords for the check, which you can override on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
UPDATE CHECK(IBMXCF,XCF_CF_ALLOCATION_PERMITTED)                        
         SEVERITY(MED) INTERVAL(004:00) DATE('date_of_the_change')
         REASON('Your reason for making the update.')
                                                               
Reference:
For more information, see z/OS MVS Setting Up a Sysplex.
Messages:
This check issues the following exception messages:
  • IXCH0212E
  • IXCH0215E
  • IXCH0206E
See the IXCH messages in z/OS MVS System Messages, Vol 10 (IXC-IZP).
SECLABEL recommended for MLS users:
SYSLOW

Go to the previous page Go to the next page