IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


CSRES_AUTOQ_GLOBALTCPIPDATA

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Description:
Checks to see if:
  • The AUTOQUIESCE operand has been specified on the UNRESPONSIVETHRESHOLD resolver setup statement and
  • The GLOBALTCPIPDATA resolver setup statement has not been specified in the resolver setup file
Reason for check:
The AUTOQUIESCE operand is ignored if the AUTOQUIESCE operand is specified on the UNRESPONSIVETHRESHOLD resolver setup statement but no GLOBALTCPIPDATA resolver setup statement is specified.
z/OS® releases the check applies to:
z/OS V1R13 and later.
User override of IBM® values:
The following shows the default keywords for the check, which you can override on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
UPDATE
CHECK(IBMCS,CSRES_AUTOQ_GLOBALTCPIPDATA)
DATE('date_of_the_change')
REASON('Your reason for making the update.')
ACTIVE
SEVERITY(LOW)
INTERVAL(ONETIME)
Debug support:
No
Verbose support:
No
Parameters accepted:
No
Reference:
For more information on AUTOQUIESCE and GLOBALTCPIPDATA resolver setup statement, see the AUTOQUIESCE and GLOBALTCPIPDATA sections in z/OS Communications Server: IP Configuration Reference.
Messages:
This check issues the following exception messages:
  • EZBH015E
See z/OS Communications Server: IP Messages Volume 2 (EZB, EZD).
SECLABEL recommended for multilevel security users:
SYSLOW - see z/OS Planning for Multilevel Security and the Common Criteria for information on using SECLABELs.

Go to the previous page Go to the next page