IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


CNZ_EMCS_Inactive_Consoles

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Description:
Ensures that there are not an excessive number of inactive EMCS consoles.
Reason for check:
If the EMCS console is no longer needed, use the EMCS console removal service (IEARELEC) to remove the EMCS console definition. The number of inactive EMCS consoles in use in a sysplex can affect the time it takes for a system to join a sysplex.
z/OS® releases the check applies to:
z/OS V1R4 and later.
User override of IBM® values:
The following shows the default keywords for the check, which you can override on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
  UPDATE,
        DATE('date_of_the_change')
        REASON('Your reason for making the update.')      
        PARM(10000)
        ACTIVE    
        SEVERITY(HI)         
        INTERVAL(24:00)
Parameters accepted:
Yes. You can specify the number of inactive EMCS consoles that you deem excessive. PARM(10000) is the default.
Reference:
For more information on EMCS consoles, see z/OS MVS Planning: Operations.
Messages:
This check issues the following exception messages:
  • CNZHF0009E
See the CNZHF messages in z/OS MVS System Messages, Vol 4 (CBD-DMO).
SECLABEL recommended for multilevel security users:
SYSLOW - see z/OS Planning for Multilevel Security and the Common Criteria for information on using SECLABELs.

Go to the previous page Go to the next page