Required parameters

SDEVN or TDEVN
Specifies the type of device to withdraw from a FlashCopy® relationship. You must specify at least one of the parameters when withdrawing a local CKD from a FlashCopy relationship. The following values are associated with these required parameters:
SDEVN
Specifies a four-digit hexadecimal device number of a local CKD device used as the FlashCopy source.
Note:
  1. If you specify the SDEVN parameter, you must also specify the TDEVN parameter, unless you also specify DDSW(YES). However, you can specify the TDEVN alone.
  2. If you specify DDSW(YES), you must specify the SDEVN parameter, in which case the TDEVN parameter is ignored.
TDEVN
Specifies a four-digit hexadecimal device number of a local CKD device used as the FlashCopy target.
DEVN
When OPENDVCS(YES) is specified, DEVN identifies a CKD access volume located in the same subsystem cluster as the open volume specified as SOURCE in this command.

When OPENDVCS(YES) and REMOTE(YES) are both specified, DEVN identifies a CKD access volume located in the same subsystem cluster as the PPRC primary paired with the PPRC secondary acting as the FlashCopy source.

When REMOTE(YES) is specified for CKD volumes ((OPENDVCS(NO) is specified or allowed to default), DEVN identifies the PPRC primary device paired with the PPRC secondary acting as FlashCopy source.

DEVN must be a 4-digit hexadecimal address of a configured device with a UCB on the System z® system issuing the command.

SOURCE
When OPENDVCS(YES) or REMOTE(YES) is specified, this identifies the source volume to be withdrawn from a FlashCopy relationship, by storage control serial number (serialno), primary volume channel connection address (CCA), and logical storage subsystem (lss).
Where:
serialno
Specifies the storage control serial number that can include up to 10 digits, depending on the type of storage control.
lss
Specifies a 2-digit hexadecimal value that specifies the logical subsystem (LSS) for the device (ESS only).
Note: The LSS number is required if the storage control supports logical subsystems (like the ESS) and not allowed if the storage control does not support logical subsystems.
cca
Specifies the 2-digit channel connection address
lun
Specifies the 2-digit hexadecimal LUN address
TARGET
When OPENDVCS(YES) or REMOTE(YES) is specified, this identifies a target volume to withdraw from a FlashCopy relationship. The descriptions for these values are the same as those shown for the SOURCE parameter.