Recovering from errors on a submit/release data set

If a submit/release data set has been damaged, follow this procedure:

  1. Stop any IBM Tivoli Workload Scheduler for z/OS subsystem that is writing to or reading from the data set.
  2. Delete the submit/release data set, and allocate a new data set.
  3. Start IBM Tivoli Workload Scheduler for z/OS again.
    Note:
    The first time IBM Tivoli Workload Scheduler for z/OS is started with a newly allocated submit/release data set, an SD37 error occurs when IBM Tivoli Workload Scheduler for z/OS formats the data set. Expect this; do not treat it as an error.
  4. Enter the Modify Current® Plan dialog, and check the status of operations in the current plan. Concentrate on computer workstations that are connected to the controller via the failing submit/release data set. If you determine that a job submission action has been missed, reset the operation to READY status.