Restoring the Application Description (AD) data set

To restore the AD data set:

  1. Stop IBM Tivoli Workload Scheduler for z/OS.
  2. Allocate a new AD data set.
  3. Copy the backup data set to the AD data set.
  4. If you allocated the data set with a new name, update all JCL (ddname EQQADDS) to reference the new AD data set.
  5. Start IBM Tivoli Workload Scheduler for z/OS.
  6. Enter the Application Description dialog to verify that applications are correctly defined. Reapply all changes since the AD backup was created.