When the client fails over to the secondary server, you can restore or retrieve replicated data from the secondary server.
To restore or retrieve data during a failover, complete the following steps:
If the replicated data on the secondary server is not current, you are prompted to continue or to stop the restore or retrieve operation.
dsmc res /build.sh
dsmc res C:\build.sh
The following
output is displayed:IBM Tivoli Storage Manager
Command Line Backup-Archive Client Interface
Client Version 7, Release 1, Level 0.0
Client date/time: 05/21/2013 14:33:54
(c) Copyright by IBM Corporation and other(s) 1990, 2013. All Rights Reserved.
Node Name: KHOYT
ANS2106I Connection to primary TSM server 192.0.2.1 failed
ANS2107I Attempting to connect to secondary server TARGET at
192.0.2.9 : 1501
Node Name: KHOYT
Session established with server TARGET: Windows
Server Version 7, Release 1, Level 0.0
Server date/time: 05/21/2013 14:33:54 Last access: 05/21/2013 14:13:32
Session established in failover mode to secondary server
ANS2108I Connected to secondary server TARGET.
Restore function invoked.
ANS2120W The last store operation date reported by the server TARGET of
05/16/2013 22:38:23 does not match the last store operation date of
05/21/2013 21:32:20 stored by the client.
Continue (Yes (Y)/No (N))
If you respond with N,
the following message is displayed:ANS1074W The operation was stopped by the user.
If
you respond with Y, restore processing continues
as normal, but the data that you restore might not be the most current.